Author:
Wu Zhen-Yu,Kim Hee Jeong,Lee Jongwon,Chung Il Yong,Kim Jisun,Lee Saebyeol,Son Byung Ho,Ahn Sei-Hyun,Kim Hak Hee,Seo Joon Beom,Jeong Jae Ho,Gong Gyungyub,Kim Namkug,Ko BeomSeok
Abstract
AbstractTo facilitate precise tumor resection at the time of breast-conserving surgery (BCS), we developed and implemented a magnetic resonance imaging (MRI)-based three-dimensional-printed (3DP) breast surgical guide (BSG). This prospective cohort study was conducted at a single institution from July 2017 to February 2019 on women with breast cancer who underwent partial breast resection using patient-specific 3DP BSGs. Eighty-eight patients with invasive cancer were enrolled, of whom 1 patient had bilateral breast cancer. The mean size of the tumor long-axis on MRI before surgery was 2.8 ± 0.9 cm, and multiple tumors were observed in 34 patients. In 16 cases (18.0%), the resection margin was tumor-positive according to intraoperative frozen biopsy; all of these tumors were ductal carcinoma in situ and were re-excised intraoperatively. In 93.3% of the cases, the resection margin was tumor-free in the permanent pathology. The mean pathological tumor size was 1.7 ± 1.0 cm, and the mean distance from the tumor to the border was 1.5 ± 1.0 cm. This exploratory study showed that the tumor area on the MRI could be directly displayed on the breast when using a 3DP BSG for BCS, thereby allowing precise surgery and safe tumor removal.Trial Registration Clinical Research Information Service (CRIS) Identifier (No. KCT0002375, KCT0003043).
Funder
Asan Institute for Life Sciences, Asan Medical Center
Publisher
Springer Science and Business Media LLC
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献