Abstract
AbstractTo determine protrusion assessment via Hertel exophthalmometry in comparison to measurement on Computed Tomography (CT). Retrospective blinded comparison of exophthalmos measurements on axial CT with Hertel exophthalmometry measurements in 113 patients. Descriptive statistics, Pearson’s correlation, Kruskal–Wallis and Mann–Whitney-U test were employed for analysis. Mean difference of proptosis between both eyes was 2.4 (SD ± 2.0) mm in CT and 2.2 (SD ± 2.0) mm in Hertel measurements. Proptosis of 0–2 mm was present in 69 (61.1%), and > 2 mm in 42 (38.9%) patients in Hertel measurements (CT 64 (56.6%), and 49 (43.4%) patients). Pearson’s coefficient showed a correlation of 0.793 between both methods (p < 0.001). Accuracy of Hertel measurement depended significantly from the examiners’ experience (< 5 (group 1), 5–15 (2) and > 25 (3) years, p = 0.042, Kruskal–Wallis analysis; p = 0.086 group 1 vs. 2, p = 0.014 group 1 vs. 3, p = 0.688 group 2 vs. 3, Mann–Whitney-U-test), reflected by levels of Pearson’s coefficient (correlation of both methods 0.691 (group 1), 0.837 (2) and 0.831 (3), respectively, p = 0.01). Generally, Hertel exophthalmometry correlates well with CT measurements. Subgroup analysis confirmed a superior quality of Hertel measurements in favour of experienced examiners. Teaching of accurate Hertel exophthalmometry should be improved. Assessment of exophthalmos using standardized criteria should be implemented for imaging reports.
Funder
Universitätsklinik München
Publisher
Springer Science and Business Media LLC
Reference15 articles.
1. Segni, M., Bartley, G. B., Garrity, J. A., Bergstralh, E. J. & Gorman, C. A. Comparability of proptosis measurements by different techniques. Am. J. Ophthalmol. 133, 813–818 (2002).
2. Ameri, H. & Fenton, S. Comparison of unilateral and simultaneous bilateral measurement of the globe position, using the Hertel exophthalmometer. Ophthal. Plast. Reconstr. Surg. 20, 448–451 (2004).
3. Hassler, W., Unsöld, R. & Schick, U. Orbital tumors—Diagnosis and surgical treatment. Dtsch. Ärztebl. 1004, 496–501 (2007).
4. Lam, A. K., Lam, C. F., Leung, W. K. & Hung, P. K. Intra-observer and interobserver variation of Hertel exophthalmometry. Ophthalmic Physiol. Opt. 29, 472–476 (2009).
5. de Juan, E., Hurley, D. P. & Sapira, J. D. Racial differences in normal values of proptosis. Arch. Intern. Med. 140, 1230–1231 (1980).
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献