Author:
Williams Dillon,Leuthardt Eric C.,Genin Guy M.,Zayed Mohamed
Abstract
AbstractArteriovenous grafts are routinely placed to facilitate hemodialysis in patients with end stage renal disease. These grafts are conduits between higher pressure arteries and lower pressure veins. The connection on the vein end of the graft, known as the graft-to-vein anastomosis, fails frequently and chronically due to high rates of stenosis and thrombosis. These failures are widely believed to be associated with pathologically high and low flow shear strain rates at the graft-to-vein anastomosis. We hypothesized that consistent with pipe flow dynamics and prior work exploring vein-to-artery anastomosis angles in arteriovenous fistulas, altering the graft-to-vein anastomosis angle can reduce the incidence of pathological shear rate fields. We tested this via computational fluid dynamic simulations of idealized arteriovenous grafts, using the Bird-Carreau constitutive law for blood. We observed that low graft-to-vein anastomosis angles ($$<20^{\circ }$$
<
20
∘
) led to increased incidence of pathologically low shear rates, and that high graft-to-vein anastomosis angles ($$>40^{\circ }$$
>
40
∘
) led to increased incidence of pathologically high shear rates. Optimizations predicted that an intermediate ($$\sim 30^\circ$$
∼
30
∘
) graft-to-anastomosis angle was optimal. Our study demonstrates that graft-to-vein anastomosis angles can significantly impact pathological flow fields, and can be optimized to substantially improve arteriovenous graft patency rates.
Funder
American Surgical Association Foundation
Society for Vascular Surgery Foundation
NIH/National Center for Advancing Translational Sciences
National Science Foundation
Center for Innovation in Neuroscience and Technology
Publisher
Springer Science and Business Media LLC
Reference53 articles.
1. Kharboutly, Z., Deplano, V., Bertrand, E. & Legallais, C. Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis. Med. Eng. Phys. 32, 111–118 (2010).
2. Brescia, M. J., Cimino, J. E., Appel, K. & Hurwich, B. J. Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula. N. Engl. J. Med. 275, 1089–1092 (1966).
3. Akoh, J. A. Prosthetic arteriovenous grafts for hemodialysis. J. Vasc. Access 10, 137–147 (2009).
4. Huber, T. S., Carter, J. W., Carter, R. L. & Seeger, J. M. Patency of autogenous and polytetrafluoroethylene upper extremity arteriovenous hemodialysis accesses: a systematic review. J. Vasc. Surg. 38, 1005–1011 (2003).
5. Azhim, A. et al. Measurement of blood flow velocity waveforms in the carotid, brachial and femoral arteries during head-up tilt. J. Biomed. Pharm. Eng. 2, 1–6 (2008).
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献