Author:
Jankowiak Kathrin,Kaifie Andrea,Krampert Thomas,Kraus Thomas,Kursawe Michael
Abstract
AbstractElectric energy is essential to today’s society. To cope with global higher demand while minimizing land use, efficient high voltage direct current (HVDC) power lines are planned to be mounted on existing alternating current (AC) structures leading to electric fields (EFs) from both AC and DC transmission lines in hybrid configurations. Due to the close proximity to residential areas, the investigation of human hybrid EF perception and underlying mechanisms will be useful to project permitting. To specify the influence of the AC component on the whole-body detection thresholds of hybrid EFs and to explore the lower bound of human hybrid EF perception, 51 participants with an EF detection ability above average were exposed in a double-blind laboratory study. A psychophysical method based on the signal detection theory was used. Very low EF strength combinations, e.g. 1 kV/m AC combined with 1 kV/m DC, were reliably perceived by at least one participant. Detection thresholds were significantly lower with increased AC EF strengths, underlining the key role of the AC component in the human perception of hybrid EFs. Findings will contribute to the assessment of public reaction to the perception of EFs around hybrid overhead power lines and to their optimal designs.
Funder
Funding was provided by Amprion GmbH, Dortmund, Germany; TenneT TSO GmbH, Bayreuth, Germany; TransnetBW GmbH, Stuttgart, Germany; and 50Hertz Transmission GmbH, Berlin, Germany.
RWTH Aachen University
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献