Development and experimental verification of C-arm camera shooting locator

Author:

Yang Jun,Yang Lin,Jon Tae Gyong,Fang Zejun,Jin Peng,Hong Zhenghua,Ye Fei,Wang Jiawen

Abstract

AbstractThis study aimed to develop a self-made C-arm camera shooting locator and verify its accuracy and advantages. A total of 60 physicians and nurses from the Surgical System of Sanmen People’s Hospital, Zhejiang Province, China, were randomly selected as filming operators. The C-arm machine with a self-made locator and a C-arm machine without a locator were used to measure the center of the circular plate. The iron nails were used to shoot. The distance between the iron nail and the center point of the circular display area on display was defined as the shooting deviation. When it was less than 3 cm, the shooting was stopped. The number of shots, total shooting time, and first-shot deviation in the C-arm camera shooting groups with and without the locator were statistically analyzed, and the advantages and disadvantages of the two were compared. The average number of shots, average total shooting time, and average first-shot deviation of the C-arm camera using the locator were significantly better than those in the group without the locator, and the differences were statistically significant. When the shooting distance (X) was equal to 30 cm and the shooting angle (Y) was equal to 0°, the average number of shots, average total shooting time, and average first-shot deviation were optimal. The C-arm camera shooting locator can improve the shooting accuracy of the C-arm camera and effectively reduce the number of shots and total shooting time. Hence, it can be applied in clinical and surgical practice.

Funder

Zhejiang Province Medicine and Health Science and Technology Program Project: Technical Achievement Project

Special research fund of "Taizhou Degenerative Osteoarthropathy Prevention and Treatment Consortium" of Taizhou Medical Key Discipline Group, Zhejiang Province

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference40 articles.

1. Meng X.Z. A laser positioning device for C-arm X-ray machine: China, ZL201520023242.2. (2015).

2. Lee, K. et al. Measurements of surgeons’ exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy. Spine 37(14), 1240–1244 (2012).

3. U.S. Food and Drug Administration. Initiative to Reduce Unnecessary Radiation Exposure from Medical Imaging. http://cllcanada.ca/2010/pages/rad_exposure.pdf. (2010–02) [2019–07–28].

4. van Rappard, J., Hummel, W. A., de Jong, T. & Mouës, C. M. A comparison of image quality and radiation exposure between the mini C-arm and the standard C-arm. Hand (New York, N.Y.) 14(6), 765–769 (2019).

5. Cretti, F. Assessment of occupational radiation dose in interventional settings. Med. Lav. 109(1), 57–67 (2018).

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献