Author:
Sohrabi Mehdi,Torkamani Morteza Ebrahimzadeh
Abstract
AbstractBreakthrough whole body energy-specific photoneutron (PN) dosimetry was made in/out-of-field in polyethylene phantom organ surface/depths remote from isocenter of 10 × 10 cm2 field prostate cancer therapy in 18 MV X-rays Varian Clinac 2100C medical linear accelerator for PN tissue-specific second primary cancer (PN-SPC) risk estimation. A novel miniature neutron dosimeter/spectrometer with polycarbonate/10B/cadmium inserts was invented and applied. Each dosimeter determines seven tissue-specific dose equivalent (mSv)/Gy X-ray dose at each measurement point providing seven major energy-specific responses for beam thermal, albedo thermal, total thermal, total epithermal, total fast, sum of totals (thermal + epithermal) and sum of totals (thermal + epithermal + fast) PNs dose equivalents. The neutron dosimeter is simple, efficient, and unique with high spatial resolution and provides matrix of energy-specific PN dose equivalent (mSv)/Gy X-ray dose on surface and organ depths for tissue-specific PN-SPC risk estimation. The dosimeter also performs like a “miniature neutron spectrometer” and is unique for other applications in health physics in particular individual neutron dosimetry, medical physics, space flights, science and technology.
Publisher
Springer Science and Business Media LLC
Reference59 articles.
1. Sohrabi, M. & Morgan, K. Z. Neutron dosimetry in high energy X-ray beams of medical accelerators. Phys. Med. Biol. 24, 756 (1979).
2. McGinley, P. & Sohrabi, M. Neutron contamination in primary beam. In Procds. of a Conference on Neutrons from Electron Medical Accelerators: Held at the National Bureau of Standards, NBS Special Publication 554; 99–110, Gaithersburg, Maryland, April 9–10 (1979).
3. Sohrabi, M. & Mostofizadeh, A. Measurement of photoneutron doses in and out of high-energy X-ray beam of a SATURNE-20 medical linear accelerator by ECE polycarbonate detectors. Radiat. Meas. 31, 479–482 (1999).
4. d’Errico, F., Luszik-Bhadra, M., Nath, R., Siebert, B. R. & Wolf, U. Depth dose-equivalent and effective energies of photoneutrons generated by 6–18 MV X-ray beams for radiotherapy. Health Phys. 80, 4–11 (2001).
5. Howell, R. M., Kry, S. F., Burgett, E., Hertel, N. E. & Followill, D. S. Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimators. Med. Phys. 36, 4027–4038 (2009).
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献