Radiation dosimetry effect evaluation of a carbon fiber couch on novel uRT-linac 506c accelerator

Author:

Jiang Dazhen,Cao Zhen,Wei Yongchang,Cao Tingting,Shen Jiuling,Xie Conghua,Zhou Yunfeng,Liu Hui,Zhang Jun

Abstract

AbstractRecently, a diagnostic helical CT is integrated into a linear accelerator, called uRT-linac 506c, whose CT scanning dataset can be directly used to do simulation. This novel structure provides a possibility for online adaptive radiotherapy. For adaptive radiotherapy, the carbon fiber couch is an essential external device for supporting and positioning patients. And the effect on dose attenuation and distribution caused by a couch is inevitable and vital for precise treatment. In this research, the couch equipped with uRT-linac 506c was evaluated on the radiation dosimetry effect. The treatment couch equipped on the uRT-linac 506c accelerator was evaluated, and its effect on the attenuation, surface dose and dose buildup were measured for different phantom positions (offset = 0 cm, offset =  + 10 cm and offset =  − 10 cm, respectively) and different gantry angles. Since uRT-linac 506c is exclusively capable to provide diagnostic CT scanning data with real relative electron density (RED), this CT scanning data of the couch can be used directly in uRT-TPS to design plans. This scanned couch dataset was designated as the model A. The model B was a dummy structure of a treatment couch inserted with artificially preset RED. The dose calculation accuracy of these two models was compared using PB, CC, and MC on uRT-TPS. With the effect of carbon fiber couch, the surface dose was increased at least 97.94% for 25 × 25 cm2 field and 188.83% for 10 × 10 cm2 field, compared with those without. At different phantom positions (offset = 0, + 10, − 10 cm), the attenuation for 6 MV photon beam at gantry angle 180° were 4.4%, 4.4%, and 4.3%, respectively, and varied with changes of gantry angle. There do exists dose deviation between measurement and TPS calculation with the involvement of treatment couch, among the three algorithms, MC presented the least deviation, and the model A made less and steadier deviation than the model B, showing promising superiority. The attenuation, surface dose, and buildup effects of the carbon fiber couch in this study were measured similarly to most counterparts. The dose deviation calculated based on the couch dataset scanned by the diagnostic helical CT was smaller than those based on a dummy couch. This result suggests that an accelerator equipped with a diagnostic CT, which can help reduce the dose deviation of the carbon fiber couch, is a promising platform for online adaptive radiotherapy.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Adaptive assessment based on fractional CBCT images for cervical cancer;Journal of Applied Clinical Medical Physics;2024-07-27

2. USAGE OF 3D PRINTER MATERIALS IN RADIOTHERAPY: DOSIMETRIC EVALUATION;International Journal of 3D Printing Technologies and Digital Industry;2023-12-31

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3