Low intensity stimulation of aortic baroreceptor afferent fibers as a potential therapeutic alternative for hypertension treatment

Author:

Salman Ibrahim M.,Ameer Omar Z.,McMurray Sheridan,Hassan Sarah F.,Sridhar Arun,Lewis Stephen J.,Hsieh Yee-Hsee

Abstract

AbstractCarotid baroreceptor stimulation has been clinically explored for antihypertensive benefits, but neuromodulation of aortic baroreceptor afferents remains unexplored for potential translation into the clinic. Published studies have used supramaximal stimulations, which are unphysiological and energy inefficient. The objective of the present study was to identify optimal low-charge nerve stimulation parameters that would provide a clinically-relevant (20–30 mmHg) decrease in mean arterial pressure (MAP) in anesthetized spontaneously hypertensive rats. Stimulations of 20 s were delivered to the left aortic depressor nerve (ADN) of these rats using low ranges of pulse amplitudes (≤ 0.6 mA), widths (≤ 0.5 ms) and frequencies (≤ 5 Hz). We also assessed the effects of continuous (20 s) versus intermittent (5 s ON/3 s OFF and 5 s ON/3 s OFF for 20 s) stimulation on MAP, heart rate (HR), mesenteric (MVR) and femoral (FVR) vascular resistance using low (5 Hz) and high (15 Hz) frequencies. Lower pulse amplitudes (0.2 mA) produced 9 ± 2 to 18 ± 2 mmHg decreases in MAP. Higher pulse amplitudes (0.4 mA) produced a median MAP reduction of 28 ± 4 mmHg at 0.2 ms and 5 Hz, with no added benefit seen above 0.4 mA. Continuous and intermittent low frequency stimulation at 0.4 mA and 0.2 ms produced similar sustained decreases in MAP, HR, MVR and FVR. Continuous high frequency stimulation at 0.4 mA and 0.2 ms produced larger reductions in MAP, HR, MVR and FVR compared with all low frequency and/or intermittent high frequency stimulations. We conclude from these findings that “low intensity intermittent” electrical stimulation is an effective alternate way for neuromodulation of the aortic baroreceptor afferents and to evoke a required restoration of MAP levels in spontaneously hypertensive rats. This approach enables low energy consumption and markedly lowers the excessive decreases in MAP and hemodynamic disturbances elicited by continuous high-charge injection protocols.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3