Seismic response analysis of super-high-rise building structures with three-layer isolation systems

Author:

Zhang Yuan,Guo Zhongfa,Liu Dewen,Sun Weiwei

Abstract

AbstractThis paper proposes a triple-layer isolation device based on the single-story isolation and double-layer isolation. By establishing dynamic equilibrium equations and conducting earthquake response comparative analyses on the same super-tall building structure using three different forms of isolation: single-story isolation, double-layer isolation, and triple-layer isolation, it is found that the triple-layer isolation device, which adds an isolation layer on the basis of the double-layer isolation device, exhibits many different characteristics in terms of its damping mechanism, seismic response rules, etc., due to the differences in the position and quantity of the isolation layer. Rare earthquakes are equivalent to ASCE maximum considered earthquake or annual occurrence probability of 2%. The research shows that, under rare earthquake conditions, the isolation effect of the triple-layer isolation device in the super-tall frame-shear structure is better than that of the single-story isolation and double-layer isolation devices. Particularly, as the number of floors increases, the triple-layer isolation device can significantly reduce the seismic isolation support tension and compression stresses, inter-story displacement, single-story shear force, overturning moment, and floor acceleration of the high-rise building structure, and concentrate the lateral displacement of the structure on the three isolation layers, dissipating most of the seismic input energy.

Funder

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference14 articles.

1. Ou, J. P., Wu, P. S. & Guan, X. C. H. Resilient structures with large displacement friction pendulum system and multi-layer isolation system. J. Disast. Prev. Mitig. Eng. 41(4), 657–76 (2021).

2. Wang, X. Q. Study on a new type of SMA-rubber bearing and its segmented isolation application in high-rise buildings (Doctoral dissertation). Liaoning Tech. Univ. China 28, 1170–1174 (2007).

3. Gao, J. P., Luo, D. & Pan, Y. Y. Optimization of passive control parameters of segmented isolation system for high-rise buildings with transition layer. J. East China Jiaotong Univ. 28(4), 23–29 (2011).

4. Wu, Q. Y., He, W. C. H. & Zhu, H. P. Effect of mixed passive control systems under different frequency domain seismic excitations on reduction and isolation. J. Lanzhou Univ. Technol. 46(2), 121–126 (2020).

5. Ryan, K. L. & Earl, C. L. Analysis and design of inter-story isolation systems with nonlinear devices. J. Earthq. Eng. 14(7), 1044–1062 (2010).