Non-invasive high frequency oscillatory ventilation inhibiting respiratory motion in healthy volunteers

Author:

Zhang Yanshan,Li Xiaojun,Zhang Yihe,Ye Yancheng,Jen Yee-Min,Pan Xin,Li Xiaowei,Qin Tianyan,Li Pengqing,Lv Caixia,Qi Ying,Wang Xin,Yang Yuling,Ma Tong

Abstract

AbstractPrecision radiotherapy needs to manage organ movements to prevent critical organ injury. The purpose of this study is to examine the feasibility of motion control of the lung by suppressing respiratory motion. The non-invasive high frequency oscillatory ventilation (NIHFOV) is a technique commonly used in the protection of lung for patients with acute lung disease. By using a very high respiratory frequency and a low tidal volume, NIHFOV allows gas exchange, maintains a constant mean airway pressure and minimizes the respiratory movements. We tested healthy volunteers NIHFOV to explore the optimal operational parameter setting and the best possible motion suppression achievable. This study was conducted with the approval of Institutional Review Boards of the Wuwei Cancer hospital (approval number: 2021-39) and carried out in accordance with Declaration of Helsinki. The study comprises two parts. Twenty three healthy volunteers participated in the first part of the study. They had 7 sessions of training with the NIHFOV. The duration of uninterrupted, continuous breathing under the NIHFOV and the optimal operational machine settings were defined. Eight healthy volunteers took part in the second part of the study and underwent 4-dimensional CT (4DCT) scanning with and without NIHFOV. Their respiratory waveform under free breathing (FB) and NIHFOV were recorded. The maximum range of motion of the diaphragm from the two scannings was compared, and the variation of bilateral lung volume was obtained to evaluate the impact of NIHFOV technique on lung volume. The following data were collected: comfort score, transcutaneous partial pressure of oxygen (PtcO2), transcutaneous partial pressure of carbon dioxide (PtcCO2), and pulse rate. Data with and without NIHFOV were compared to evaluate its safety, physiological impacts and effect of lung movement suppression. All the volunteers completed the training sessions eventlessly, demonstrating a good tolerability of the procedure. The median NIHFOV-on time was 32 min (22–45 min), and the maximum range of motion in the cephalic-caudal direction was significantly reduced on NIHFOV compared with FB (1.8 ± 0.8 cm vs 0.3 ± 0.1 cm, t =  − 3.650, P = 0.003); the median range of motion was only 0.3 ± 0.1 cm on NIHFOV with a good reproducibility. The variation coefficient under NIHFOV of the right lung volume was 2.4% and the left lung volume was 9.2%. The PtcO2 and PtcCO2 were constantly monitored during NIHFOV. The medium PtcCO2 under NIHFOV increased lightly by 4.1 mmHg (interquartile range [IQR], 4–6 mmHg) compared with FB (t = 17.676, P < 0.001). No hypercapnia was found, PtcO2 increased significantly in all volunteers during NIHFOV (t = 25.453, P < 0.001). There was no significant difference in pulse rate between the two data sets (t = 1.257, P = 0.233). NIHFOV is easy to master in healthy volunteers to minimize respiratory movement with good tolerability and reproducibility. It is a feasible approach for lung motion control and could potentially be applied in accurate radiotherapy including carbon-ion radiotherapy through suppression of respiratory movement.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3