Author:
Sukanya S. D.,Swamy B. E. Kumara,Shashikumara J. K.,Sharma S. C.,Hariprasad S. A.
Abstract
AbstractIn the present work, Orange CD was chosen as an intriguing modifier for the electropolymerization on the surface of CPE by the CV technique. A novel, sensitive, and cost-effective poly (Orange CD) MCPE (PoOCD/MCPE) sensor was utilized for the selective detection of paracetamol (PA) in 0.2 M phosphate buffer solution (PBS) of pH 7.4. The oxidation peak current of PA was vastly enhanced at the sensor. The scan rate study is suggested that electro-oxidation of PA was adsorption-controlled. The pH study testifies the redox pathways transport with the same quantity of electrons and protons. The detection limit of PA is found to be 2.64 µM. DPV results show that substantial peak separation between PA, folic acid (FA), and dopamine (DA) could be facilitating their individual and simultaneous determination on the sensor. The decorated sensor demonstrates high sensitivity, stability, reproducibility, repeatability and has been successfully exploited for the detection of PA in a tablet with promising results.
Publisher
Springer Science and Business Media LLC
Reference54 articles.
1. Beitollahi, H. & Sheikhshoaie, I. Novel nanostructure-based electrochemical sensor for simultaneous determination of dopamine and acetaminophen. Mater. Sci. Eng. C. 32, 375–380 (2012).
2. Teradale, A. B., Ganesh, P. S., KumaraSwamy, B. E. & Das, S. N. Application of poly (nicotinamide) modified carbon paste electrode sensor for the electrocatalytic determination of acetaminophen and folic acid. Anal. Bioanal. Electrochem. 10, 203–219 (2018).
3. Tanuja, S. B., KumaraSwamy, B. E. & Pai, K. V. Electrochemical determination of paracetamol in presence of folic acid at nevirapine modified carbon paste electrode: A cyclic voltammetric study. J. Electroanal. Chem 798, 17–23 (2017).
4. Song, Y., Zhang, Y., Li, J., Tan, C. & Li, Y. Preparation of poly ionic liquid-mesoporous carbon nanospheres and its application in simultaneous determination of hydroquinone and catechol, and detection of paracetamol. J. Electroanal. Chem. 865, 114157 (2020).
5. Mahmoud, B. G., Khairy, M., Rashwan, F. A. & Banks, C. E. Simultaneous voltammetric determination of acetaminophen and isoniazid (hepatotoxicity-related drugs) utilizing bismuth oxide nanorod modified screen-printed electrochemical sensing platforms. Anal. Chem. 89, 2170–2178 (2017).
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献