Estimating cardiac output based on gas exchange during veno-arterial extracorporeal membrane oxygenation in a simulation study using paediatric oxygenators

Author:

Bachmann Kaspar Felix,Vasireddy Rakesh,Heinisch Paul Philipp,Jenni Hansjörg,Vogt Andreas,Berger David

Abstract

AbstractVeno-arterial extracorporeal membrane oxygenation (VA-ECMO) therapy is a rescue strategy for severe cardiopulmonary failure. The estimation of cardiac output during VA-ECMO is challenging. A lung circuit ($${\dot{\text{Q}}}$$ Q ˙ Lung) and an ECMO circuit ($${\dot{\text{Q}}}$$ Q ˙ ECMO) with oxygenators for CO2 removal ($$\mathop {\text{V}}\limits^{.}$$ V . CO2) and O2 uptake ($$\mathop {\text{V}}\limits^{.}$$ V . O2) simulated the setting of VA-ECMO with varying ventilation/perfusion ($$\mathop {\text{V}}\limits^{.}$$ V . /$${\dot{\text{Q}}}$$ Q ˙ ) ratios and shunt. A metabolic chamber with a CO2/N2 blend simulated $$\mathop {\text{V}}\limits^{.}$$ V . CO2 and $$\mathop {\text{V}}\limits^{.}$$ V . O2. $${\dot{\text{Q}}}$$ Q ˙ Lung was estimated with a modified Fick principle: $${\dot{\text{Q}}}$$ Q ˙ Lung = $${\dot{\text{Q}}}$$ Q ˙ ECMO × ($$\mathop {\text{V}}\limits^{.}$$ V . CO2 or $$\mathop {\text{V}}\limits^{.}$$ V . O2Lung)/($$\mathop {\text{V}}\limits^{.}$$ V . CO2 or $$\mathop {\text{V}}\limits^{.}$$ V . O2ECMO). A normalization procedure corrected $$\mathop {\text{V}}\limits^{.}$$ V . CO2 values for a $$\mathop {\text{V}}\limits^{.}$$ V . /$${\dot{\text{Q}}}$$ Q ˙ of 1. Method agreement was evaluated by Bland–Altman analysis. Calculated $${\dot{\text{Q}}}$$ Q ˙ Lung using gaseous $$\mathop {\text{V}}\limits^{.}$$ V . CO2 and $$\mathop {\text{V}}\limits^{.}$$ V . O2 correlated well with measured $${\dot{\text{Q}}}$$ Q ˙ Lung with a bias of 103 ml/min [− 268 to 185] ml/min; Limits of Agreement: − 306 ml/min [− 241 to − 877 ml/min] to 512 ml/min [447 to 610 ml/min], r2 0.85 [0.79–0.88]). Blood measurements of $$\mathop {\text{V}}\limits^{.}$$ V . CO2 showed an increased bias (− 260 ml/min [− 1503 to 982] ml/min), clinically not applicable. Shunt and $$\mathop {\text{V}}\limits^{.}$$ V . /$${\dot{\text{Q}}}$$ Q ˙ mismatch decreased the agreement of methods significantly. This in-vitro simulation shows that $$\mathop {\text{V}}\limits^{.}$$ V . CO2 and $$\mathop {\text{V}}\limits^{.}$$ V . O2 in steady-state conditions allow for clinically applicable calculations of $${\dot{\text{Q}}}$$ Q ˙ Lung during VA-ECMO therapy.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3