Evaluating the performance characteristics of five lateral flow assays for the detection of the SARS-CoV-2 nucleocapsid antigen

Author:

Heskin J.,Pallett S. J. C.,Al-Hindawi A.,Davies G. W.,Rayment M.,Mughal N.,Randell P.,Jones R.,Moore L. S. P.

Abstract

AbstractIn response to the COVID-19 pandemic, lateral flow assays (LFAs) for the detection of SARS-CoV-2 antigen have been proposed as a complementary option to the more costly and time consuming reverse-transcriptase polymerase chain reaction (RT-PCR). We assessed five commercially available SARS-CoV-2 antigen detecting LFAs (ASSUT EUROPE (Rome, Italy), Besthree (Taizhou, China), Encode (Zhuhai, China), Fortress (Antrim UK), and Hughes Medical (Buckinghamshire, UK), using samples collected from hospitalised individuals with COVID-19 and compared these results against established RT-PCR assays with the aim of estimating test performance characteristics. We performed a diagnostic accuracy study of the five LFAs on 110 inpatients with confirmed COVID-19 and 75 COVID-19 negative control participants. Assay evaluation was performed using a modified version of each manufacturer’s protocol allowing for parallel testing of a single sample on multiple assays. Additional variables were studied including infection acquisition, oxygenation requirements at time of swabbing, and patient outcomes. The 110 patients were 48% (53) female, with mean age 67 years (range 26–100 years), and 77% (85) cases were community onset SARS-CoV-2. Across the five assays, sensitivity ranged from 64 (95% CI 53–73) to 76% (95% CI 65–85); Fortress performed best with sensitivity of 76% (95% CI 65–85). Specificity was high across all assays with 4/5 LFAs achieving 100%. LFA sensitivity was not dependant on RT-PCR cycle thresholds. SARS-CoV-2 antigen detecting LFAs may complement RT-PCR testing to facilitate early diagnosis and provide community testing strategies for identification of patients with COVID-19, however we find suboptimal test performance characteristics across a range of commercially available manufacturers, below WHO and MHRA pre-set sensitivity performance thresholds. With such variation in sensitivity between LFAs and PCR testing and between assay brands, we advise caution in the deployment of LFAs outside of environments with clinical oversight.

Funder

CW+

Westminster Medical School Research Trust

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference16 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3