Comprehensive evaluation of artifact reduction and tissue recovery effects of metal artifact reduction technique based on full-reference metric

Author:

Jung Yunsub,Song You Seon,Lee In Sook,Rhee Seung Joon

Abstract

AbstractFor the comprehensive evaluation of metal artifact reduction (MAR) technique, not only the removal of metal artifacts but also the evaluation of the area restored by MAR is required. We propose a method to comprehensively evaluate the effect by MAR in this study. We have conducted the computed tomography scan to acquire both the evaluation image and the reference image for the full-reference based evaluation. The evaluation image and reference image were reconstructed into 24 image sets according to the tube potentials, image reconstruction method, and use of the MAR technique. Images of two different positions were selected according to the distance from metal and material (bone, tissue) distribution, and bone and tissue were automatically segmented in both evaluation and reference images. The values of full width at half the maximum (FWHM) and centroid were extracted after Gaussian modeling of each segmented region. Then, we computed four evaluation metrics (FWHMNM: non-MAR to non-metal ratio of FWHM, FWHMM: MAR to non-metal ratio of FWHM, CENTNM: non-MAR to non-metal ratio of centroid, CENTM: MAR to non-metal ratio of centroid), and the MAR image and non-MAR image were compared. The overlap ratio automatically segmented from the evaluation image and reference image were position 1 (bone: 99.61%, tissue: 99.23%) with 80 kVp, position 1 (bone: 99.32%, tissue: 99.56%) with 120 kVp, position 2 (bone: 99.20%, tissue: 99.73%) with 80 kVp, and position 2 (bone: 99.23%, tissue: 99.67%) with 120 kVp. The FWHMNM showing the change of image pixel value by metal artifact was calculated as (bone: 1.32–1.46, tissue: 1.08–1.16) at 80 kVp and (bone: 1.19–1.27, tissue: 1.02–1.05) at 120 kVp. More metal artifacts occurred at 80 kVp tube potential. Regardless of the tube potential and image reconstruction method, the MAR showed an overall artifact reduction effect (1 < FWHMM < FWHMNM). However, distortion of pixel values occurred due to the MAR in regions where metal artifacts were high in proximity to metal (1 < FWHMNM < FWHMM). Overall, the average value of the medium was maintained (CENTM: 0.98–1.03) after MAR application, but there was a change of image value in region around the metal (CENTM: 0.97–1.11). In this study, we propose a new method to evaluate the effect of metal artifacts and MAR technique using full-reference based method. Metal artifacts, effect of MAR technique, and side-effect caused by MAR technique were quantitatively analyzed through proposed method. There are some limitations in applying it to clinical imaging since our method is a reference-based evaluation. However, our experimental results were important for understanding the effects of the MAR technique and its functional properties.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3