Author:
Mebrahtom Misgina,Fissha Yewuhalashet,Ali Mujahid,Gebretsadik Angesom,Kide Yemane,Nguse Zaid,Gebrehiwot Zemicael,Flores Erick Saavedra,Avudaiappan Siva,Ikeda Hajime
Abstract
AbstractRecent and past studies mainly focus on reducing the dead weight of structure; therefore, they considered lightweight aggregate concrete (LWAC) which reduces the dead weight but also affects the strength parameters. Therefore, the current study aims to use varied steel wire meshes to investigate the effects of LWAC on mechanical properties. Three types of steel wire mesh are used such as hexagonal (chicken), welded square, and expanded metal mesh, in various layers and orientations in LWAC. Numerous mechanical characteristics were examined, including energy absorption (EA), compressive strength (CS), and flexural strength (FS). A total of ninety prisms and thirty-three cubes were made. For the FS test, forty-five 100 × 100 × 500 mm prism samples were poured, thirty-three 150 × 150 × 150 mm cube samples were made, and forty-five 400 × 300 × 75 mm EA specimens were costed for fourteen days of curing. The experimental findings demonstrate that the FS was enhanced by adding additional forces that spread the forces over the section. One layer of chicken, welded, and expanded metal mesh enhances the FS by 52.96%, 23.76%, and 22.2%, respectively. In comparison to the remaining layers, the FS in a single-layer hexagonal wire mesh has the maximum strength, 29.49 MPa. The hexagonal wire mesh with a single layer had the greatest CS, measuring 36.56 MPa. When all three types of meshes are combined, the CS does not vary in this way and is estimated to be 29.79 MPa. In the combination of three layers, the chicken and expanded wire mesh had the most energy recorded prior to final failure, which was 1425.6 and 1108.7 J, whereas it was found the highest 752.3 J for welded square wire mesh. The energy absorption for the first layer with hexagonal wire mesh increased by 82.81% prior to the crack and by 88.34% prior to the ultimate failure. Overall, it was determined and suggested that hexagonal wire mesh works better than expanded and welded wire meshes.
Publisher
Springer Science and Business Media LLC
Reference51 articles.
1. Ali, M. et al. Central composite design application in the optimization of the effect of waste foundry sand on concrete properties using RSM. Structures 46, 1581–1594. https://doi.org/10.1016/j.istruc.2022.11.013 (2022).
2. Shah, S. et al. Mechanical behaviour of E-waste aggregate concrete using a novel machine learning algorithm: Multi expression programming (MEP). J. Mater. Res. Technol. 25, 5720–5740. https://doi.org/10.1016/j.jmrt.2023.07.041 (2023).
3. Murali, G. et al. Low-velocity impact response of novel prepacked expanded clay aggregate fibrous concrete produced with carbon nano tube, glass fiber mesh and steel fiber. Constr. Build. Mater. 284, 122749. https://doi.org/10.1016/j.conbuildmat.2021.122749 (2021).
4. Alexander, D. The durability of ferrocement and fibrous ferrocement in aggressive environments. J. Ferrocem. 22, 373–373 (1992).
5. Sakthivel, P. & Jagannathan, A. Ferrocement construction technology and its applications—A Review. (2011).
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献