Standardized distances for placement of REBOA in patients with aortic stenosis

Author:

Olsen Markus Harboe,Thonghong Tasalak,Søndergaard Lars,Møller Kirsten

Abstract

AbstractResuscitative endovascular balloon occlusion of the aorta (REBOA) is a technique where a balloon is advanced through the common femoral artery and temporarily inflated for treatment of cardiac arrest or non-compressible haemorrhage. The aim of this study was to measure intravascular distances relevant for correct placement of the REBOA catheter using computer tomographic (CT) scans. In a series of CT scans of the aorta from 100 patients diagnosed with severe aortic stenosis planned for transcatheter aortic valve implantation, we measured the intravascular distance from the insertion site in the common femoral artery to two potential zones for placement of the REBOA catheter; between the left subclavian artery and the celiac trunk (Zone 1), as well as between the aortic bifurcation and the distal take-off of the renal arteries (Zone 3). The mean (± SD) intravascular distance from the femoral artery to intra-aortic Zone 1 was 36 (± 2.5) cm for the lower border and 60 (± 4.1) cm for the upper border, respectively. For intra-aortic Zone 3, the mean (± SD) intravascular distance was 21 (± 2.1) cm to the lower border and 31 (± 2.3) cm to the upper border. Calculated potentially safe intervals for placement of the REBOA in Zone 1 was with 99.7% likelihood between 43 and 48 cm. No similar potentially safe interval could be calculated for Zone 3. According to this cohort study of patients with severe aortic stenosis, the balloon of the REBOA catheter should travel intraarterially between 43 (lower limit) and 48 cm (upper limit) from the site of insertion into the common femoral artery, which would lead to correct placement in intra-aortic Zone 1 in 99.7% of cases. In contrast, no potential safety interval could be similarly defined for insertion in Zone 3.

Funder

Dr. Olsen reports grants from Neurescue, during the conduct of the study as well as outside the submitted work.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3