Abstract
AbstractIn order to analyze the influence of eccentric load on mechanical properties and damage process of concrete with initial damage, the eccentric load compression tests of concrete under different confining pressures were carried out with the help of PFC particle flow program. The results show that: the eccentric load does not change the relationship between peak stress, crack initiation stress and confining pressure of concrete under uniform load, but decrease the value of them. The peak stress increasing coefficient under uniform load is higher than that under eccentric load, and the peak stress increasing coefficient increases in a linear function with the confining pressure, and the increasing rate is approximately the same. Under uniaxial compression of eccentric load, a type I shear crack approximately parallel to the loading direction is formed, while under biaxial compression, a bending type shear crack with the lower tip of the initial crack as the inflection point is formed. The number of microcracks in concrete under uniform load and eccentric load can be divided into three stages: the calm period at the initial loading stage, the pre-peak expansion period from crack initiation point to peak point, and the rapid increase period after the peak.
Funder
National Natural Science Foundation of China
Discipline Innovation Team of Liaoning Technical University
Liaoning province Department of Education fund item
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献