Author:
Mansouri Abraham,Binali Alreem Essa,Khan Najeeb,Zamanzadeh Mehrooz,Taheri Peyman
Abstract
AbstractThe design of sacrificial cathodic protection (CP) systems conventionally involves steady-state assumptions, which means design parameters are considered constant during the in-service life of CP systems. In contrast, it is evident by experimental observations (including field measurements) that cathodic protection is a transient process due to variations in electrolyte properties such as seasonal changes in electrical conductivity of soil, depletion of anodes, and formation of corrosion deposits on anode material surface, to name a few. The lack of practical time-dependent models on this critical issue is apparent in the literature; accordingly, in this study, a pseudo transient electrochemical model is adopted to highlight the transient behavior of cathodic protection systems and investigate key differences with steady-state behavior. For the sake of demonstration, the developed model is used to simulate the time-dependent performance of a sacrificial anode bed for cathodic protection of screw-pile foundations. The methodology proposed in this study can be used by corrosion engineers to improve and optimize the design of CP systems and numerically estimate the performance of sacrificial anodes and the level of protection over time.
Publisher
Springer Science and Business Media LLC
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献