Author:
Schaufler Anna,Sanin Ahmed Y.,Sandalcioglu I. Erol,Hartmann Karl,Croner Roland S.,Perrakis Aristotelis,Wartmann Thomas,Boese Axel,Kahlert Ulf D.,Fischer Igor
Abstract
AbstractCurrent treatment for glioblastoma includes tumor resection followed by radiation, chemotherapy, and periodic post-operative examinations. Despite combination therapies, patients face a poor prognosis and eventual recurrence, which often occurs at the resection site. With standard MRI imaging surveillance, histologic changes may be overlooked or misinterpreted, leading to erroneous conclusions about the course of adjuvant therapy and subsequent interventions. To address these challenges, we propose an implantable system for accurate continuous recurrence monitoring that employs optical sensing of fluorescently labeled cancer cells and is implanted in the resection cavity during the final stage of tumor resection. We demonstrate the feasibility of the sensing principle using miniaturized system components, optical tissue phantoms, and porcine brain tissue in a series of experimental trials. Subsequently, the system electronics are extended to include circuitry for wireless energy transfer and power management and verified through electromagnetic field, circuit simulations and test of an evaluation board. Finally, a holistic conceptual system design is presented and visualized. This novel approach to monitor glioblastoma patients is intended to early detect recurrent cancerous tissue and enable personalization and optimization of therapy thus potentially improving overall prognosis.
Funder
Volkswagen Foundation
Heinrich-Heine-Universität Düsseldorf
Publisher
Springer Science and Business Media LLC
Reference57 articles.
1. Moore, G. E. Fluorescein as an agent in the differentiation of normal and malignant tissues. Science 106, 130–131 (1947).
2. Neira, J. A. et al. Aggressive resection at the infiltrative margins of glioblastoma facilitated by intraoperative fluorescein guidance. Journal of Neurosurgery 127, 111–122 (2016).
3. Figge, F. & Weiland, G. The affinity of neoplastic, embryonic, and traumatized tissue for porphyrins and metalloporphyrins. In Anatomical record 100, 659–659, (Wiley-liss div john wiley & Sons Inc, 1948).
4. Gregorie, H. Jr. et al. Hematoporphyrin-derivative fluorescence in malignant neoplasms. Annals of surgery 167, 820 (1968).
5. Klinger, J. & Katz, R. Tetracycline fluorescence in the diagnosis of gastric carcinoma: preliminary report. Gastroenterology 41, 29–32 (1961).
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献