Author:
Demircioğlu Aydin,Quinsten Anton S.,Umutlu Lale,Forsting Michael,Nassenstein Kai,Bos Denise
Abstract
AbstractIn this retrospective study, we aimed to predict the body height and weight of pediatric patients using CT localizers, which are overview scans performed before the acquisition of the CT. We trained three commonly used networks (EfficientNetV2-S, ResNet-18, and ResNet-34) on a cohort of 1009 and 1111 CT localizers of pediatric patients with recorded body height and weight (between January 2013 and December 2019) and validated them in an additional cohort of 116 and 127 localizers (acquired in 2020). The best-performing model was then tested in an independent cohort of 203 and 225 CT localizers (acquired between January 2021 and March 2023). In addition, a cohort of 1401 and 1590 localizers from younger adults (acquired between January 2013 and December 2013) was added to the training set to determine if it could improve the overall accuracy. The EfficientNetV2-S using the additional adult cohort performed best with a mean absolute error of 5.58 ± 4.26 cm for height and 4.25 ± 4.28 kg for weight. The relative error was 4.12 ± 4.05% for height and 11.28 ± 12.05% for weight. Our study demonstrated that automated estimation of height and weight in pediatric patients from CT localizers can be performed.
Funder
Deutsche Forschungsgemeinschaft
Universitätsklinikum Essen
Publisher
Springer Science and Business Media LLC
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献