Author:
Teng Guangping,Shi Guoqing,Zhu Jintuo,Zhao Caijun
Abstract
AbstractIn the hope of reducing the air supply flow of the powered air-purifying respirator (PAPR) and extending the service life of the filter, a breath-following powered air-purifying respirator (BF-PAPR) that can dynamically adjust the air supply flow according to the breathing flow is proposed. The BF-PAPR changes the air supply flow by adjusting the speed of the variable-frequency centrifugal fan according to the air velocity at the half mask outlet (vhm) monitored by the modular wind speed transmitter. In the study, the air supply flow adjustment model of the BF-PAPR is developed. It is found that the filtration resistance barely influences vhm. In addition, under the same mean inhalation flow, the minimum outlet air velocity increases first and then decreases with the increase of the duty cycle variation coefficient (λ), while the maximum outlet air velocity decreases first and then increases. Moreover, the minimum air supply flow of the BF-PAPR is achieved when the standard value of the air velocity is 13.4 m/s and the value of λ is 1. The BF-PAPR can reduce the air supply flow by 6.5%-8.6% and the energy consumption by approximately 20% compared with the PAPR, which is beneficial for reducing the usage cost and extending the continuous working time.
Funder
National Natural Science Foundation of China
Fundamental Research Funds for the Central Universities
Basic Research Program of Jiangsu Province
Natural Science Project of Hunan Institute of Technology
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献