Clinical evaluation of non-contact infrared thermometers

Author:

Sullivan Stacey J. L.,Rinaldi Jean E.,Hariharan Prasanna,Casamento Jon P.,Baek Seungchul,Seay Nathanael,Vesnovsky Oleg,Topoleski L. D. Timmie

Abstract

AbstractNon-contact infrared thermometers (NCITs) are being widely used during the COVID-19 pandemic as a temperature-measurement tool for screening and isolating patients in healthcare settings, travelers at ports of entry, and the general public. To understand the accuracy of NCITs, a clinical study was conducted with 1113 adult subjects using six different commercially available NCIT models. A total of 60 NCITs were tested with 10 units for each model. The NCIT-measured temperature was compared with the oral temperature obtained using a reference oral thermometer. The mean difference between the reference thermometer and NCIT measurement (clinical bias) was different for each NCIT model. The clinical bias ranged from just under − 0.9 °C (under-reporting) to just over 0.2 °C (over-reporting). The individual differences ranged from − 3 to + 2 °C in extreme cases, with the majority of the differences between − 2 and + 1 °C. Depending upon the NCIT model, 48% to 88% of the individual temperature measurements were outside the labeled accuracy stated by the manufacturers. The sensitivity of the NCIT models for detecting subject’s temperature above 38 °C ranged from 0 to 0.69. Overall, our results indicate that some NCIT devices may not be consistently accurate enough to determine if subject’s temperature exceeds a specific threshold of 38 °C. Model-to-model variability and individual model accuracy in the displayed temperature were found to be outside of acceptable limits. Accuracy and credibility of the NCITs should be thoroughly evaluated before using them as an effective screening tool.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference14 articles.

1. Management of Ill Travellers at Points of Entry: International Airports, Seaports and Ground Crossings—In the Context of the COVID-19 Outbreak (World Health Organization, 2019).

2. ASTM E1965-98. Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature. (ASTM International, West Conshohocken, PA, 2016).

3. ISO 80601-2-56:2017. Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement.

4. FDA. Clinical Electronic Thermometer. Product Classification. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPCD/classification.cfm?ID=FLL (2019). Accessed 22 Apr 2020.

5. Dante, A., Franconi, I., Marucci, A. R., Alfes, C. M. & Lancia, L. Evaluating the interchangeability of forehead, tympanic, and axillary thermometers in italian paediatric clinical settings: Results of a multicentre observational study. J. Pediatr. Nurs. 52, e21–e25. https://doi.org/10.1016/j.pedn.2019.11.014 (2020).