Author:
Planeta Karolina,Kubala-Kukus Aldona,Drozdz Agnieszka,Matusiak Katarzyna,Setkowicz Zuzanna,Chwiej Joanna
Abstract
AbstractThe fundamental role of major, minor and trace elements in different physiological and pathological processes occurring in living organism makes that elemental analysis of biomedical samples becomes more and more popular issue. The most often used tools for analysis of the elemental composition of biological samples include Flame and Graphite Furnace Atomic Absorption Spectroscopy (F-AAS and GF-AAS), Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Each of these techniques has many advantages and limitations that should be considered in the first stage of planning the measurement procedure. Their reliability can be checked in the validation process and the precision, trueness and detection limits of elements belong to the most frequently determined validation parameters. The main purpose of this paper was the discussion of selected instrumental techniques (F-AAS, GF-AAS, ICP-OES and ICP-MS) in term of the achieved validation parameters and the usefulness in the analysis of biological samples. The focus in the detailed literature studies was also put on the methods of preparation of the biomedical samples. What is more based on the own data the usefulness of the total reflection X-ray fluorescence spectroscopy for the elemental analysis of animal tissues was examined. The detection limits of elements, precision and trueness for the technique were determined and compared with the literature data concerning other of the discussed techniques of elemental analysis. Reassuming, the following paper is to serve as a guide and comprehensive source of information concerning the validation parameters achievable in different instrumental techniques used for the elemental analysis of biomedical samples.
Publisher
Springer Science and Business Media LLC
Reference153 articles.
1. Penner, M. H. Basic principles of spectroscopy. In Food Analysis (Springer International Publishing, Berlin, 2017).
2. Taylor, H. E. Inductively Coupled Plasma-Mass Spectrometry. Practices and Techniques (Academic Press, New York, 2001).
3. Rahil-Khazen, R., Bolann, B. J., Myking, A. & Ulvik, R. J. Multi-element analysis of trace element levels in human autopsy tissues by using inductively coupled atomic emission spectrometry technique (ICP-AES). J. Trace Elem. Med Biol. 16, 15–25 (2002).
4. Zimmermann, S., Messerschmidt, J., von Bohlen, A. & Sures, B. Determination of Pt, Pd and Rh in biological samples by electrothermal atomic absorption spectrometry as compared with adsorptive cathodic stripping voltammetry and total-reflection X-ray fluorescence analysis. Anal. Chim. Acta 498, 93–104 (2003).
5. Stephan, C. H., Fournier, M., Brousseau, P. & Sauvé, S. Graphite furnace atomic absorption spectrometry as a routine method for the quantification of beryllium in blood and serum. Chem. Central J. https://doi.org/10.1186/1752-153X-2-14 (2008).
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献