Author:
Shih Po-Jen,Wu Shao-Jie,Sung Ya-Hsing,Tung Yu-Ting,Chang Chia-Yu,Hatamie Shadie,Dai Zhi-Xuan
Abstract
AbstractThe eye orbit has mechanical and acoustic characteristics that determine resonant frequencies and amplify acoustic signals in certain frequency ranges. These characteristics also interfere with the acoustic amplitudes and frequencies of eyeball when measured with an acoustic tonometer. A model in which a porcine eyeball was embedded in ultrasonic conductive gel in the orbit of a model skull was used to simulate an in vivo environment, and the acoustic responses of eyeballs were detected. The triggering source was a low-power acoustic speaker contacting the occipital bone, and the detector was a high-resolution microphone with a dish detecting the acoustic signals without contacting the cornea. Dozens of ex vivo porcine eyeballs were tested at various intraocular pressure levels to detect their resonant frequencies and acoustic amplitudes in their power spectra. We confirmed that the eyeballs’ resonant frequencies were proportional to intraocular pressure, but interference from orbit effects decreased the amplitudes in these resonant frequency ranges. However, we observed that the frequency amplitudes of eyeballs were correlated with intraocular pressure in other frequency ranges. We investigated eye orbit effects and demonstrated how they interfere with the eyeball’s resonant frequencies and frequency amplitudes. These results are useful for developing advanced acoustic tonometer.
Funder
Collaborative Research Projects of National Taiwan University College of Medicine, National Taiwan University Hospital and Min-Sheng General Hospital
Publisher
Springer Science and Business Media LLC
Reference27 articles.
1. Forbes, M., Pico, G. & Grolman, B. A noncontact applanation tonometer: Description and clinical evaluation. Arch. Ophthalmol. 91, 134–140 (1974).
2. Kim, D. et al. A pilot study for intraocular pressure measurements based on vibroacoustic parameters. Sci. Rep. 11, 1264. https://doi.org/10.1038/s41598-020-80321-1 (2021).
3. von Freyberg, A. et al. Acoustic tonometry: Feasibility study of a new principle of intraocular pressure measurement. J. Glaucoma 18, 316–320 (2009).
4. Krakau, C. E. T. A vibration tonometer. Ophthalmic Res. 1, 129–139. https://doi.org/10.1159/000264510 (1970).
5. Somerville, P., Collins, N., Graves, R. & Pitarka, A. in Proceedings of the 13th World Conference on Earthquake Engineering.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献