Author:
Han Shaoyang,Wang Baotian,Wang Yu,Liu Wenpeng,Chen Chenghao,Zhang Yijiang
Abstract
AbstractAn improved electroosmotic method is proposed in this paper to enhance the non-uniform effect and efficiency of electroosmotic process. Such method is electroosmotic flow with injection of calcium chloride through the anode, followed by injection through the central tube (a tube at the midpoint between the anode and the cathode) with a suitable time interval between injections. Experimental results indicate that using this method can significantly improve the non-uniform reduction in water content throughout the soil, mitigate the formation of cracks in the anode section, and therefore considerably inhibit the increase in the electric resistance. After treatment, the drained water could be raised to 3.59 times more than that of pure electroosmotic flow, and 1.3 times that of simultaneous injection through both the anode and the central tube with considerably slight increase in power consumption. Moreover, the area of cementation was also expanded, approximately twice larger than that of pure electroosmotic flow and one and a half that of simultaneous injection. It is also worth noting that the proposed method performs better with the same power consumption. The results demonstrate that electroosmotic flow with a suitable time interval between injections could improve the efficiency of electroosmotic process and expand the treatment region in soils, hence can be a promising and economic technique for soil improvement in practical engineering.
Funder
National Natural Science Foundation of China
Foundation of Nanjing Hydraulic Research Institute
Publisher
Springer Science and Business Media LLC