Author:
Alachkar Mhd Nawar,Alnaimi Anas,Reith Sebastain,Altiok Ertunc,Schröder Jörg,Marx Nikolaus,Almalla Mohammad
Abstract
AbstractPercutaneous mitral valve repair (PMVR) requires transseptal puncture and results in iatrogenic atrial septal defect (iASD). The impact of persistent iASD was previously investigated. However, data were diverse and inconclusive. 53 patients who underwent MITRACLIP were retrospectively included. Based on the presence of iASD in transesophageal echocardiography (TEE) after 6 months, patients were divided in two groups (iASD group vs. non-iASD group). Impact of iASD on outcome at 6 months and at two years was evaluated. Persistent iASD was detected in 62% of patients. Independent predictors for persistent iASD were female gender and reduced left ventricular ejection fraction. At 6-month follow-up, there was no difference in reduction of NYHA class (ΔNYHA = 1.3 ± 1 in iASD group vs. 0.9 ± 1 in non-iASD group, p = 0.171). There was a significant difference in right ventricular end diastolic diameter (RVEDd) (42 ± 8 mm in iASD-group vs. 39 ± 4 mm in non-iASD group, p = 0.047). However, right ventricular systolic function (TAPSE) (14 ± 7 mm in iASD group vs. 16 ± 8 mm in non-iASD group, p = 0.176) and right ventricular systolic pressure (RVSP) (40 ± 12 mmHg in iASD group vs. 35 ± 10 mmHg in non-iASD group, p = 0.136) were still comparable between both groups. At 2 years follow-up, there was no significant difference regarding rate of rehospitalization (24% vs 15%, p = 0.425) or mortality (12% vs 10%, p = 0.941) between both groups. Incidence of persistent iASD after MITRACLIP is markedly high. Despite the increase in right ventricular diameter in patients with persistent iASD, these patients were not clinically compromised compared to patients without persistent iASD.
Publisher
Springer Science and Business Media LLC
Reference25 articles.
1. Boekstegers, P. et al. Percutaneous interventional mitral regurgitation treatment using the Mitra-clip system. Clin. Res. Cardiol. 103(2), 85–96 (2014).
2. Ansari, M. T., Ahmadzai, N., Coyle, K., Coyle, D. & Moher, D. Mitral valve clip for treatment of mitral regurgitation: An evidence-based analysis. Ont. Health Technol. Assess Ser. 15(12), 1–104 (2015).
3. Feldman, T. et al. Percutaneous repair or surgery for mitral regurgitation. N. Engl. J. Med. 364, 1395–1406 (2021).
4. Sherif, M. A. et al. MitraClip step by step; how to simplify the procedure. Neth. Heart J. 25(2), 125–130 (2017).
5. Smith, T. et al. Prevalence and echocardiographic features of iatrogenic atrial septal defect after catheter-based mitral valve repair with the MitraClip system. Catheter Cardiovasc. Interv. 80(4), 678–685 (2012).
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献