Comparison of Cerebral Blood Flow Acquired by Simultaneous [15O]Water Positron Emission Tomography and Arterial Spin Labeling Magnetic Resonance Imaging

Author:

Zhang Ke1,Herzog Hans1,Mauler Jörg1,Filss Christian1,Okell Thomas W2,Kops Elena Rota1,Tellmann Lutz1,Fischer Thomas3,Brocke Burkhard3,Sturm Walter4,Coenen Heinz H56,Shah N Jon146

Affiliation:

1. Institute of Neuroscience and Medicine—4: Medical Imaging Physics, Forschungszentrum Jülich, Jülich, Germany

2. FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK

3. Department of Psychology, Dresden University of Technology, Dresden, Germany

4. Department of Neurology, University of Aachen, Aachen, Germany

5. Institute of Neuroscience and Medicine—5: Nuclear Chemistry, Forschungszentrum Jülich, Jülich, Germany

6. JARA Brain—Translational Brain Medicine, Germany

Abstract

Until recently, no direct comparison between [15O]water positron emission tomography (PET) and arterial spin labeling (ASL) for measuring cerebral blood flow (CBF) was possible. With the introduction of integrated, hybrid magnetic resonance (MR)-PET scanners, such a comparison becomes feasible. This study presents results of CBF measurements recorded simultaneously with [15O]water and ASL. A 3T MR-BrainPET scanner was used for the simultaneous acquisition of pseudo-continuous ASL (pCASL) magnetic resonance imaging (MRI) and [15O]water PET. Quantitative CBF values were compared in 10 young healthy male volunteers at baseline conditions. A statistically significant ( P<0.05) correlation was observed between the two modalities; the whole-brain CBF values determined with PET and pCASL were 43.3 ±6.1 mL and 51.9 ± 7.1 mL per 100 g per minute, respectively. The gray/white matter (GM/WM) ratio of CBF was 3.0 for PET and 3.4 for pCASL. A paired t-test revealed differences in regional CBF between ASL and PET with higher ASL-CBF than PET-CBF values in cortical areas. Using an integrated, hybrid MR-PET a direct simultaneous comparison between ASL and [15O]water PET became possible for the first time so that temporal, physiologic, and functional variations were avoided. Regional and individual differences were found despite the overall similarity between ASL and PET, requiring further detailed investigations.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Neurology (clinical),Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3