Comparison of continuous measures across diagnostic PD-L1 assays in non-small cell lung cancer using automated image analysis

Author:

Widmaier Moritz,Wiestler Tobias,Walker Jill,Barker Craig,Scott Marietta L.,Sekhavati Farzad,Budco Alexei,Schneider Katrin,Segerer Felix J.,Steele Keith,Rebelatto Marlon C.

Abstract

Abstract Tumor programmed cell death ligand-1 (PD-L1) expression is a key biomarker to identify patients with non-small cell lung cancer who may have an enhanced response to anti-programmed cell death-1 (PD-1)/PD-L1 treatment. Such treatments are used in conjunction with PD-L1 diagnostic immunohistochemistry assays. We developed a computer-aided automated image analysis with customized PD-L1 scoring algorithm that was evaluated via correlation with manual pathologist scores and used to determine comparability across PD-L1 immunohistochemistry assays. The image analysis scoring algorithm was developed to quantify the percentage of PD-L1 positive tumor cells on scans of whole-slide images of archival tumor samples from commercially available non-small cell lung cancer cases, stained with four immunohistochemistry PD-L1 assays (Ventana SP263 and SP142 and Dako 22C3 and 28-8). The scans were co-registered and tumor and exclusion annotations aligned to ensure that analysis of each case was restricted to comparable tissue areas. Reference pathologist scores were available from previous studies. F1, a statistical measure of precision and recall, and overall percentage agreement scores were used to assess concordance between pathologist and image analysis scores and between immunohistochemistry assays. In total, 471 PD-L1-evalulable samples were amenable to image analysis scoring. Image analysis and pathologist scores were highly concordant, with F1 scores ranging from 0.8 to 0.9 across varying matched PD-L1 cutoffs. Based on F1 and overall percentage agreement scores (both manual and image analysis scoring), the Ventana SP263 and Dako 28-8 and 22C3 assays were concordant across a broad range of cutoffs; however, the Ventana SP142 assay showed very different characteristics. In summary, a novel automated image analysis scoring algorithm was developed that was highly correlated with pathologist scores. The algorithm permitted quantitative comparison of existing PD-L1 diagnostic assays, confirming previous findings that indicate a high concordance between the Ventana SP263 and Dako 22C3 and 28-8 PD-L1 immunohistochemistry assays.

Funder

AstraZeneca

Publisher

Springer Science and Business Media LLC

Subject

Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3