Abstract
AbstractThis work investigates the estimation biases of remote photoplethysmography (rPPG) methods for pulse rate measurement across diverse demographics. Advances in photoplethysmography (PPG) and rPPG methods have enabled the development of contact and noncontact approaches for continuous monitoring and collection of patient health data. The contagious nature of viruses such as COVID-19 warrants noncontact methods for physiological signal estimation. However, these approaches are subject to estimation biases due to variations in environmental conditions and subject demographics. The performance of contact-based wearable sensors has been evaluated, using off-the-shelf devices across demographics. However, the measurement uncertainty of rPPG methods that estimate pulse rate has not been sufficiently tested across diverse demographic populations or environments. Quantifying the efficacy of rPPG methods in real-world conditions is critical in determining their potential viability as health monitoring solutions. Currently, publicly available face datasets accompanied by physiological measurements are typically captured in controlled laboratory settings, lacking diversity in subject skin tones, age, and cultural artifacts (e.g, bindi worn by Indian women). In this study, we collect pulse rate and facial video data from human subjects in India and Sierra Leone, in order to quantify the uncertainty in noncontact pulse rate estimation methods. The video data are used to estimate pulse rate using state-of-the-art rPPG camera-based methods, and compared against ground truth measurements captured using an FDA-approved contact-based pulse rate measurement device. Our study reveals that rPPG methods exhibit similar biases when compared with a contact-based device across demographic groups and environmental conditions. The mean difference between pulse rates measured by rPPG methods and the ground truth is found to be ~2% (1 beats per minute (b.p.m.)), signifying agreement of rPPG methods with the ground truth. We also find that rPPG methods show pulse rate variability of ~15% (11 b.p.m.), as compared to the ground truth. We investigate factors impacting rPPG methods and discuss solutions aimed at mitigating variance.
Funder
Bill and Melinda Gates Foundation
Publisher
Springer Science and Business Media LLC
Subject
Health Information Management,Health Informatics,Computer Science Applications,Medicine (miscellaneous)
Reference61 articles.
1. Rolfe, P., Zhang, Y. & Sun, J. Invasive and non-invasive measurement in medicine and biology: calibration issues. In Proc. of Sixth International Symposium on Precision Engineering Measurements and Instrumentation, Vol. 7544, International Society for Optics and Photonics, 754454 (SPIE, 2010).
2. Burritt, M. F. Noninvasive and invasive sensors for patient monitoring. Lab. Med. 29, 684–687 (1998).
3. Raluca, M. A., Pasca, S. & Strungaru, R. Heart rate monitoring by using non-invasive wearable sensor. In 2017 E-Health and Bioengineering Conference (EHB), 587–590 (IEEE, 2017).
4. Bhavnani, A., Chiu, R. W., Janakiram, S., Silarszky, P. & Bhatia, D. The role of mobile phones in sustainable rural poverty reduction http://documents.worldbank.org/curated/en/644271468315541419/The-role-of-mobile-phones-in-sustainable-rural-poverty-reduction (2008).
5. Taylor, W. et al. A review of the state of the art in non-contact sensing for covid-19. Sensors 20, 5665 (2020).
Cited by
45 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献