Improved Power Sharing Strategy for Parallel Connected Inverters in Standalone Micro-grid

Author:

Gaddameedhi Sravanthy1,Susheela N.2

Affiliation:

1. Department of Electrical and Electronics Engineering, Sreenidhi Institute of Science and Technology, Telangana, India

2. Department Electrical and Electronics Engineering, Osmania University, Telangana, India

Abstract

The primary goal of integrating alternative energy systems such as solar and wind turbines into the power grid using power electronic devices is to meet the growing energy demands. Connecting inverters in parallel effectively enhance power capacity, reliability, and overall system efficiency. However, an uneven power distribution among the inverters is a significant limitation in these parallel connected inverters (PCI). This study focuses on a distributed generation (DG) unit comprising a solar photovoltaic system (SPV) and a battery energy storage system (BESS) connected to voltage source inverters (VSI) 1 and 2. The proposed approach aims to achieve uniform load/power distribution among the inverters with power management, maintaining a constant DC link voltage despite variations in solar irradiation and temperature. Additionally, the strategy targets the reduction of total harmonic distortion (THD) in the load current. The conventional droop control method is restricted in its ability to achieve accurate and uniform power distribution during load changes. An enhanced P-f and Q-E-based droop control technique (EDCT) and a fuzzy logic controller (FLC) have been proposed to address these challenges. Performance analysis using MATLAB/Simulink was conducted with two test cases, and a comparative assessment was carried out with a conventional controller, such as a Proportional Integral Controller (PIC) and Sliding Mode Controller (SMC), to showcase the effectiveness of the developed control technique. The proposed control method ensures equal sharing of active power of 2.5 and 4kW, 2.5 and 7.5kW and reactive powers of 2.5 and 4Vars, 2.5 and 7.5Vars among the inverters for the two cases even during the load change at t=0.5seconds. The settling time for DC link voltage and THD is effectively diminished to 0.03 and 0.25 seconds and 1.18% and 2.87% for the two test case studies of the proposed method, which are much lower than those of existing methods available in the literature.

Publisher

FOREX Publication

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3