In vivo evaluation of an implantable portal pump system for augmenting liver perfusion

Author:

Jiao L R1,Seifalian A M2,Davidson B R2,Habib N1

Affiliation:

1. Liver Surgery Unit, Imperial College School of Medicine, Hammersmith Hospital, London, UK

2. University Department of Surgery, Royal Free and University College Medical School, London, UK

Abstract

Abstract Background Increasing portal inflow in cirrhosis using a mechanical pump reduces portal venous pressure and improves liver function. A pump has been developed for portal vein implantation in human cirrhosis. This study describes the initial in vivo evaluation in a porcine model. Methods Five Large White pigs underwent laparotomy and exposure of the liver. Flow in the hepatic artery, portal vein and hepatic microcirculation was monitored continuously. Hepatic tissue oxygenation was measured by near-infrared spectroscopy. After baseline measurements the pump was inserted into the portal vein. Pump flow rate was then increased stepwise to 50 per cent over the baseline value for a period of 2 h. The pump was then stopped for 20 min and left in situ while continuing to collect systemic and hepatic haemodynamic data. The animal was killed and biopsies for histological examination were taken from the liver, small intestine and spleen. Results The baseline total hepatic blood flow was 626(39) ml/min; the hepatic artery supplied 18·4(2·1) per cent and the portal vein 81·6(2·1) per cent. The pump was inserted successfully in all animals without surgical complications. During surgical insertion of the pump, the temporary portal vein occlusion resulted in a significant rise in hepatic artery blood flow (22(3) per cent; P < 0·01 versus baseline). Portal vein flow was augmented by pumping; there was a significant correlation between the pump motor speed and portal vein flow (P < 0·0001). This inflow correlated directly with flow in the hepatic microcirculation and hepatic tissue oxygenation (P < 0·001). The pump ran satisfactorily throughout the study. Histological examination revealed no evidence of structural damage to the liver or ischaemic changes in the small intestine or spleen. Conclusion It is technically possible and safe to insert an implantable pump in the portal vein. Portal venous blood flow can be increased up to 50 per cent with a resultant increase in flow in the hepatic microcirculation and hepatic oxygenation and without adverse effects on either hepatic or systemic haemodynamics.

Publisher

Oxford University Press (OUP)

Subject

Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3