Can Clinician-Stabilization with Hand-Held Dynamometry Yield a Reliable Measure of Knee Flexion Torque?

Author:

Larson Daniel1ORCID,Lorenz Daniel1,Melton Brittany2

Affiliation:

1. OrthoKansas/Lawrence Memorial Hospital

2. University of Kansas

Abstract

Background Assessment of knee flexion torque is a relevant clinical measure following various injuries and surgeries to determine progress in rehabilitation and inform decision making. A variety of methods using hand-held dynamometry have been shown to be reliable in obtaining this measure, and typically require a means of external fixation or stabilization. Clinically efficient methods of reliable clinician-stabilization are sparse in the literature. Hypothesis/Purpose Determine inter and intra-rater reliability of two clinically efficient methods of assessing isometric knee flexion torque using hand-held dynamometry with clinician-stabilization. The hypothesis was that each method would yield good to excellent reliability. Study Design Cross-Sectional Study Methods Twenty healthy individuals were assessed by two clinicians on two separate days. During each session, knee flexion torque was assessed with hand-held dynamometry with two methods: 1) in the seated position with the hip and knee flexed to 90 degrees while the clinician stabilized the dynamometer between the participant’s leg and table and 2) in prone with the hip at 0 degrees and knee at 90 degrees while the clinician assumed a stride stance with elbows locked in extension to stabilize the dynamometer on the participant’s leg. Inter and intra-rater reliability were determined for each method. Results ICC values were 0.88-0.94 and 0.77-0.90 for inter and intra-rater reliability respectively with the seated method. The prone method yielded ICC values of 0.84-0.96 and 0.89-0.94 for inter and intra-rater reliability respectively. MDC values ranged from 30-62% with the seated method and 21-40% with the prone method. Conclusion Inter and intra-rater reliability were good to excellent for assessing knee flexion torque with hand-held dynamometry using both the seated and prone methods with clinically efficient clinician-stabilization approaches. The prone method may be more sensitive to detecting change over time due to lower MDC values. Level of Evidence 2b

Publisher

International Journal of Sports Physical Therapy

Subject

Rehabilitation,Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3