Reliability of the EasyAngle® for Assessing Hip Range of Motion in Healthy Children

Author:

Duffy Elana1,Wells Maria1,Miller Alan1,Tondra Megan1,Doty Antonette1

Affiliation:

1. Walsh University

Abstract

Background The use of digital goniometry has emerged as a viable alternative to universal goniometry for assessing hip range of motion (ROM). However, few studies have assessed the use of digital goniometry in pediatric populations and there are a limited number of studies that investigate any one device. The EasyAngle® is a digital goniometer that may be beneficial for use in pediatric settings as it requires only one hand to operate the device. Purpose The purposes of this study were 1) to establish the intrarater and interrater reliability of the EasyAngle® digital goniometer in measuring hip joint ROM in healthy elementary school-aged children, and 2) to establish preliminary normative reference values for each year of age using the EasyAngle® for hip joint ROM in healthy elementary school-aged children. Study Design Descriptive Laboratory Study Methods Passive hip ROM (flexion, abduction, extension, internal rotation, external rotation) was measured on each leg of healthy participants using the EasyAngle®. A total of 40 hip joints were measured. Two blinded raters conducted three trials of each hip motion on both legs. Intrarater and interrater reliability of the recorded hip range of motion were calculated using intra-class correlation coefficients (ICC) (3,1). Results Twenty healthy children were measured (age 5-10, mean = 7.40 years old, SD = 1.37, 9 males, 11 females). Mean hip ROM was reported by age. Intrarater and interrater reliability were good to excellent for all hip ROM measurements (0.81-0.97 intra rater; 0.77- 0.91 interrater). Hip flexion had the strongest intrarater (0.96, 0.97) and interrater reliability (0.91). Intrarater reliability was lowest for hip abduction for Rater 1 and hip extension for Rater 2. Interrater reliability was lowest for hip external rotation (0.78) Conclusion The EasyAngle® is a reliable tool for assessing hip range of motion in healthy children ages 5-10. Normative hip ROM values using the EasyAngle® are available to clinicians. Level of Evidence Level 3- Reliability study

Publisher

International Journal of Sports Physical Therapy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3