Validity, Agreement and Reliability of the ForceFrame Dynamometer in Patients with Anterior Cruciate Ligament Injury

Author:

Arp Kamilla12,Frydendal Thomas34,Kjeldsen Troels34,Dalgas Ulrik4,Timm Signe1,Viberg Bjarke51,Ingwersen Kim1,Varnum Claus21

Affiliation:

1. Lillebaelt Hospital

2. University of Southern Denmark

3. Aarhus University Hospital

4. Aarhus University

5. Odense University Hospital

Abstract

Background Restoring maximal muscle strength of the knee extensors (KE) and knee flexors (KF) following anterior cruciate ligament (ACL) injury and ACL reconstruction is of great importance to reduce the re-injury rate after ACL reconstruction and to reduce the risk of knee osteoarthritis. Therefore, it is essential that clinicians and healthcare providers use valid and reliable measures to assess knee muscle strength to ensure a safe return to sport. Purpose To evaluate the reliability (test-retest reliability, inter-tester reliability and test-retest agreement) and validity (concurrent validity, convergent validity and ForceFrame (FF) vs. isokinetic dynamometer (ID) agreement) of the ForceFrame (FF) dynamometer during isometric testing of the knee extensors and flexors. Study Design Cross-sectional study Material and Methods Twenty-seven participants with ACL injury or reconstruction were recruited for participation in this study. maximal voluntary isometric contration (MVIC) of the knee extensors and flexors was tested on two separate days. Day one included validity assessments with FF, a gold-standard ID and a handheld dynamometer (HHD). Day two included reliability assessments with FF performed by two assessors. Main outcome measures were day-to-day test-retest reliability and agreement and inter-tester reliability of FF, and concurrent validity (FF vs. an ID and a HHD). Reliability was tested as test-retest and inter-tester reliability using interclass correlation coefficient (ICC), while agreement was tested using Bland & Altman plots with limits of agreement (LOA), standard error of measurement (SEM) and smallest detectable change (SDC). Concurrent validity between FF, ID, and HHD was assessed using Pearson’s correlations and mean difference was evaluated by Bland & Altman plots. Results Twenty-seven participants (10 females, 17 males) with a median age of 25 years (range 19-60) were included in this study. There was a good day-to-day test-retest reliability for MVIC of KE (ICC=0.77, CI95:0.48-0.90) and KF (ICC=0.83, CI95:0.61-0.92) and excellent inter-tester reliability for MVIC of KE (ICC=0.97, CI95:0.94-0.98) and KF (ICC=0.93, 95CI:0.85-0.97). Standard error of measurement (SEM) was 8% and 9%, while the smallest detectable change (SDC) was 22% and 27% for KE and KF, respectively. FF showed fair concurrent validity compared to ID for KE (r=0.56), poor concurrent validity for knee flexors (KF (r=0.24) and compared to HHD a moderate correlation for KE (r=0.74) and poor correlation for KF (r=0.12). Bland & Altman plots between FF and the ID showed a mean difference of -0.51 Nm/kg for KE and -0.32Nm/kg for KF. Conclusions FF can be used to obtain reliable and valid results to assess MVIC of the KE, but not the KF. It should be noted that absolute results produced by the FF may be considered an underestimation of actual MVIC. The test position to assess KF in FF does not appear to be optimal, and different test-positions may be considered. Level of evidence Level 3

Publisher

International Journal of Sports Physical Therapy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3