Agreement Between Isokinetic Dynamometer and Hand-held Isometric Dynamometer as Measures to Detect Lower Limb Asymmetry in Muscle Torque After Anterior Cruciate Ligament Reconstruction

Author:

Ivarsson Angelica1,Cronström Anna12

Affiliation:

1. Lund University

2. Umeå University, Umeå, Sweden

Abstract

Background Two commonly used instruments to assess muscle strength after anterior cruciate ligament reconstruction are the isokinetic dynamometer, which measures isokinetic torque and the hand-held dynamometer, which measures isometric torque. Isokinetic dynamometers are considered superior to other instruments but may not be commonly used in clinical settings. Hand-held dynamometers are small, portable, and more clinically applicable devices. Purpose The purpose of this study was to assess agreement between a hand-held dynamometer and an isokinetic dynamometer, used to assess lower limb symmetry in knee muscle torque one year after anterior cruciate ligament (ACL) reconstruction. Study design Cross-sectional measurement study Methods Seventy-two participants who had undergone ACL reconstruction (35 men, 37 women; age= 25.8 ± 5.4 years) were included. Isokinetic muscle torque in knee flexion and extension was measured with an isokinetic dynamometer. Isometric flexion and extension knee muscle torque was measured with a hand-held dynamometer. Bland & Altman plots and Cohen’s Kappa coefficient were used to assess agreement between measurements obtained from the instruments. Result Bland & Altman plots showed wide limits of agreement between the instruments for both flexion and extension limb symmetry index. Cohen´s Kappa coefficient revealed a poor to slight agreement between the extension limb symmetry index values (0.136) and a fair agreement for flexion limb symmetry index values (0.236). Cross-tabulations showed that the hand-held dynamometer detected a significantly larger number of participants with abnormal flexion torque limb symmetry index compared to the isokinetic dynamometer. Conclusion The wide limits of agreements and Cohen’s Kappa coefficients values revealed insufficient agreement between the measurements taken with the two instruments, indicating that the instruments should not be used interchangeably. The hand-held dynamometer was more sensitive in detecting abnormal limb symmetry index in flexion torque, which promotes the option of use of hand-held dynamometers to detect differences between the injured and uninjured leg after ACL reconstruction. Level of evidence 3b

Publisher

International Journal of Sports Physical Therapy

Subject

Rehabilitation,Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3