The Validity and Reliability of a Smartphone Application for Break-Point Angle Measurement during Nordic Hamstring Exercise

Author:

Soga Toshiaki1ORCID,Yamaguchi Shota2ORCID,Inami Takayuki2ORCID,Saito Hiromi1ORCID,Hakariya Nadaka1,Nakaichi Naoto1,Shinohara Sho1,Akiyama Kei1ORCID,Hirose Norikazu1ORCID

Affiliation:

1. Waseda University

2. Keio University

Abstract

Background A recently developed smartphone application (Nordic Angle) allows the automatic calculation of the break-point angle (BPA) during Nordic hamstring exercise (NHE) without transferring the collected data to a computer. The BPA is the point at which the hamstrings are unable to withstand force. However, the validity of the BPA values obtained by this method has not been examined. Hypothesis/Purpose This study aimed to evaluate the validity and reliability of the Nordic Angle by comparing the BPA values of the Nordic Angle with those of two-dimensional motion analysis software that can calculate the angles and angular velocities of various joints. Study Design Cohort assessing Validity and Reliability Methods The validity of the Nordic Angle BPA data was verified by Spearman’s correlation test for consistency with the movement analysis data, and the magnitude of the correlation was indicated by rs. The agreement between these measurements was examined using the Bland-Altman analysis. The reliability of the Nordic Angle and motion analysis was examined using the intraclass correlation coefficient (ICC) (1,k) based on data from repeated trials within a day. Results Although the spearman correlation between the Nordic angle and the angle determined using motion analysis did not reach statistical significance (p = 0.052), a very large correlation was present (rs = 0.75). The difference between the mean values of the Nordic Angle and motion analysis was 0.4 ± 2.1°, and the limits of agreement ranged from -3.9° to 4.6°. In two BPA measurements, the Nordic Angle showed perfect reliability (ICC = 1.00, p < 0.001), while motion analysis showed nearly perfect reliability (ICC = 0.97, p < 0.001). Conclusion The Nordic Angle, which has both validity and reliability, may be appropriate for field measurement because it allows immediate feedback of BPA and the measurement of many athletes. Level of evidence 3b

Publisher

International Journal of Sports Physical Therapy

Subject

Rehabilitation,Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Considering the Validity and Reliability Testing of a Digital Punch Measuring Tool in Young Combat Athletes;Physical Education Theory and Methodology;2024-09-10

2. Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord);Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology;2024-04-09

3. Hamstring Activity Before and After Break-Point Angle Calculated By Smartphone Application During the Nordic Hamstring Exercise;International Journal of Sports Physical Therapy;2023-12-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3