Maximal and Explosive Muscle Strength During Hip Adduction Squeeze and Hip Abduction Press Test Using A Handheld Dynamometer: An Intra- and Inter-tester Reliability Study

Author:

Ishøi Lasse1,Thorborg Kristian1,Krohn Laura1,Louis Andersen Lars2,Møller Nielsen Asger1,Bek Clausen MIkkel13

Affiliation:

1. Copenhagen University Hospital

2. National Research Centre for the Working Environment

3. University College Copenhagen

Abstract

Background Hip adduction and abduction muscle function plays an important role for risk of groin pain in athletes. Maximal isometric strength can be obtained clinically using a handheld dynamometer. However, in very strong athletes this is challenging, as external fixation of the dynamometer is needed for reliable measures. An alternative to unilateral testing, is the long-lever hip adduction squeeze test and a novel bilateral hip abduction press test. While promising intra-tester reliability has been found for maximal strength during the long-lever hip adduction squeeze test, inter-tester reliability may be more challenging during both maximal and explosive strength measurements. Hypothesis/purpose The aim of the present study was to assess intra- and inter-tester reliability of maximal, and explosive strength during the long lever hip adduction squeeze test and the long lever hip abduction press test in healthy adults using a hand-held dynamometer. Study design Intra- and interrater reliability study. Methods Forty-nine healthy subjects were included for intra- (n=20) and inter-tester reliability (n=29). Subjects performed the hip adduction long lever squeeze test and the bilateral hip abduction press test in a randomized order. Maximal isometric strength and early (0-100 ms) and late (0-200 ms) phase rate of force development (explosive muscle strength) was obtained using a hand-held dynamometer. Relative reliability for all tests was assessed using ICC2,1 two-way mixed model with absolute agreement, thereby taking bias between testers into account. Results Maximal isometric strength showed good intra- and inter-tester reliability for adduction (ICC: 0.93-0.97) and abduction (ICC: 0.88-0.92). For 0-200 ms rate of force development, both the squeeze and press test showed good intra-tester reliability (ICC: 0.85-0.87), whereas inter-tester reliability was good for hip adduction squeeze (ICC: 0.75) and moderate for hip abduction press (ICC: 0.71). For 0-100 ms rate of force development, the hip abduction press test showed good intra-tester reliability (ICC: 0.78). Remaining tests for intra- and inter-tester reliability showed moderate reliability (ICC: 0.50-0.71). Conclusion Assessment of maximal isometric strength in hip adduction squeeze and abduction press test showed good intra- and inter-tester reliability, whereas only 0-200 ms rate of force development demonstrated good intra-tester reliability of both tests. Therefore, rate of force development should preferably be conducted by the same tester, while the long lever squeeze and press test can reliably be used within- and between testers to measure maximal isometric strength. Level of Evidence 3

Publisher

International Journal of Sports Physical Therapy

Subject

Rehabilitation,Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3