Pretargeting For The Implantation Of Stimulation Electrodes Into The Subthalamic Nucleus:A Comparative Study Of Magnetic Resonance Imaging And Ventriculography

Author:

Breit Sorin1,LeBas Jean-Francois2,Koudsie Adnan3,Schulz Jo¨rg4,Benazzouz Abdelhamid5,Pollak Pierre6,Benabid Alim-Louis7

Affiliation:

1. INSERM U.318, Department of Neurobiology, University Joseph Fourier, Grenoble, France Department of Neurodegeneration, Center of Neurology and Hertie Institute for Clinical Brain Research, University of Tu¨bingen, Tu¨bingen, Germany

2. Department of Neuroradiology, University Joseph Fourier, Grenoble, France

3. Department of Neurosurgery, University Joseph Fourier, Grenoble, France

4. Department of Neurology, Center of Neurology and Hertie Institute for Clinical Brain Research, University of Tu¨bingen, Tu¨bingen, Germany

5. INSERM U.318, Department of Neurobiology, University Joseph Fourier, Grenoble, France

6. Department of Neurology, University Joseph Fourier, Grenoble, France

7. INSERM U.318, Department of Neurosurgery and Neurobiology, University Joseph Fourier, Grenoble, France

Abstract

Abstract OBJECTIVE: The optimal imaging modality for preoperative targeting of the subthalamic nucleus (STN) for high-frequency stimulation is controversially discussed. Commonly used methods were stereotactic magnetic resonance imaging (MRI), stereotactic ventriculography, and fusion between MRI and stereotactic computer tomography. All of these techniques not only have their own advantages but also specific limitations and drawbacks. The purpose of this study was to evaluate the accuracy of the preoperative MRI targeting as compared with ventriculography in terms of both the STN target as well as the internal landmarks. METHODS: Thirty patients with Parkinson's disease who underwent bilateral surgery for STN-high-frequency stimulation received both stereotactic ventriculography and stereotactic MRI. The theoretical target was determined by each of these two imaging modalities. The final electrode placement was performed after extensive electrophysiological evaluation using microrecording and microstimulation. The real target was assumed to be given by the electrode contact with the best clinical result assessed by the United Parkinson's Disease Rating Scale in the postoperative follow-up. In addition, the coordinates of the two landmarks, anterior commissure and posterior commissure, were determined using both imaging methods. RESULTS: The mean targeting error was 4.1 ± 1.7 mm (mean ± standard deviation) for MRI and 2.4 ± 1.1 mm for ventriculography (P < 0.0001). The mean target mismatch between the two imaging methods was 2.9 ± 1.2 mm. The length of the anterior commissure-posterior commissure distance differed significantly (P < 0.0001) between MRI (27.6 ± 1.6 mm) and ventriculography (25.0 ± 1.3 mm). The mismatch was mainly induced by an anterior diplacement of the anterior commissure by 1.9 ± 2.2 mm (P < 0.0001) in MRI determination, as compared with ventriculography. CONCLUSION: Our findings show that the indirect targeting of the STN using coordinates based on radiological landmarks is more accurate than the direct targeting using anatomic visualization of the target structure. Regardless of the imaging procedure, electrophysiological mapping is required for optimal electrode placement, although in 20% of cases, the target determined by MRI falls out of the radius explored by electrophysiology.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 39 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3