Recanalization of Obstructed Cerebrospinal Fluid Ventricular Catheters Using Ultrasonic Cavitation

Author:

Ginsberg Howard J.1,Drake James M.2,Peterson Thomas M.3,Cobbold Richard S.C.4

Affiliation:

1. Division of Neurosurgery, St. Michaels Hospital, and Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada

2. Division of Neurosurgery, Hospital for Sick Children, Toronto, Canada

3. Cybersonics Inc., Erie, Pennsylvania

4. Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada

Abstract

Abstract OBJECTIVE: Fifty percent of implanted cerebrospinal fluid (CSF) shunts fail within 2 years, primarily because of obstruction of the proximal catheter. Percutaneous techniques to reduce the morbidity of shunt revision are being developed. The authors describe the development of a device that uses ultrasonic cavitation to unblock ventricular catheters. METHODS: In collaboration with Cybersonics, Inc. (Erie, PA), we designed, built, and tested a system that produces low-frequency ultrasound (20–28 kHz). Extensional ultrasonic waves are transmitted along a tapered wire (final diameter, approximately 0.8 mm) to the tip, where cavitation is produced in a highly localized region. An in vitro model of sheep choroid plexus occluding typical ventricular catheters was developed. The device was safety tested in vivo in rat and pig brains by introducing the device into shunt catheters inserted during simulated shunt surgery. A clinical safety trial using the device to attempt to remove blocked and adherent ventricular catheters has commenced. RESULTS: In the sheep choroid plexus model, at least 90% of the occluded holes were unblocked in a few minutes, restoring normal flow. There was no adverse effect of the device within shunt catheters inserted into live animal brains. Four patients have undergone treatment with the device at open CSF shunt surgery without adverse effect, and the device seems effective at unblocking and freeing the occluded catheters. CONCLUSION: Ultrasonic cavitation produced at the end of a fine wire that is introduced percutaneously into a CSF shunt promises to be a useful technique for minimally invasive proximal ventricular CSF shunt catheter revision.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3