Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing. Part II: Thoracolumbar Spine

Author:

Scheufler Kai-Michael1,Franke Joerg2,Eckardt Anke3,Dohmen Hildegard4

Affiliation:

1. Department of Neurosurgery, Medical University Innsbruck, Innsbruck, Austria

2. Department of Orthopedic Surgery, University Hospital Magdeburg, Magdeburg, Germany

3. Department of Orthopedic Surgery, Hirslanden Klinik Birshof, Bale, Switzerland

4. Department of Neuropathology, University Hospital Zürich, Zürich, Switzerland

Abstract

Abstract BACKGROUND Image-guided spinal instrumentation may reduce complications in spinal instrumentation. OBJECTIVE To assess accuracy, time efficiency, and staff radiation exposure during thoracolumbar screw instrumentation guided by intraoperative computed tomography (iCT)-based neuronavigation (iCT-N). METHODS In 55 patients treated for idiopathic and degenerative deformities, 826 screws were inserted in the thoracic (T2–T12; n = 243) and lumbosacral (L1–S1; n = 545) spine, as well as ilium (n = 38) guided by iCT-N. Up to 17 segments were instrumented following a single automated registration sequence with the dynamic reference arc (DRA) uniformly attached to L5. Accuracy of iCT-N was assessed by calculating angular deviations between individual navigated tool trajectories and final implant positions. Final screw positions were also graded according to established classification systems. Clinical and radiological outcome was assessed at 12 to 14 months. RESULTS Additional intraoperative fluoroscopy was unnecessary, eliminating staff radiation exposure. Unisegmental K-wire insertion required 4.6 ± 2.9 minutes. Of the thoracic pedicle screws 98.4% were assigned grades I to III according to the Heary classification, with 1.6% grade IV placement. In the lumbar spine, 94.4% of screws were completely contained (Gertzbein classification grade 0), 4.6% displayed minor pedicle breaches <2 mm (grade 1), and 1% of lumbar screws deviated by >2 to <4 mm (grade 2). The accuracy of iCT-N progressively deteriorates with increasing distance from the DRA, but allows safe instrumentation of up to 12 segments. CONCLUSION iCT-N using automated referencing allows for safe, highly accurate multilevel instrumentation of the entire thoracolumbosacral spine and ilium, rendering additional intraoperative imaging dispensable. In addition, automated registration is time-efficient and significantly reduces the need for re-registration in multilevel surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3