Premature Adjacent Vertebral Fracture After Vertebroplasty: A Biomechanical Study

Author:

Fahim Daniel K1,Sun Kay2,Tawackoli Wafa3,Mendel Ehud4,Rhines Laurence D5,Burton Allen W6,Kim Daniel H1,Ehni Bruce L7,Liebschner Michael A. K1

Affiliation:

1. Department of Neurosurgery, Baylor College of Medicine, Houston, Texas

2. Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee

3. Cedars Sinai Medical Center, Los Angeles, California

4. Department of Neurosurgery, Ohio State University, Columbus, Ohio

5. Department of Neurosurgery, M.D. Anderson Cancer Center, Houston, Texas

6. Houston Pain Associates, Houston, Texas

7. Neurosurgery Service Line, Michael E. DeBakey VA Medical Center, Houston, Texas

Abstract

Abstract BACKGROUND: There is an increased incidence of fractures in untreated adjacent vertebrae after vertebroplasty. OBJECTIVE: To introduce unconstrained 6 degrees of freedom biomechanical testing to investigate whether vertebroplasty lowered the fracture strength of adjacent untreated vertebrae under physiological loading conditions and to describe the observed fracture pattern. METHODS: Three-level spinal segments (T10-12 and L1–3) from 6 spines were tested under unconstrained axial compression in which shear forces and torque were minimized using a 6-degrees of freedom robotic arm. Fracture initiation loads and ultimate failure loads of lumbar segments were predicted from the corresponding thoracic segments by assuming constant fracture stress along the spinal column. The predicted values were compared with postvertebroplasty experimental values of the lumbar spine segments. Plain radiographs were taken at 600-N increments to record the developing fracture pattern. RESULTS: All 6 vertebroplasty group specimens experienced reductions in fracture strengths ranging from 27.4% to 47.6% with an average decrease of 32.6% (P < .002) and reductions in ultimate failure load ranging from 1.6% to 47.3%, with an average decrease of 34.7% (P < .003) compared with predicted values from the nonvertebroplasty group. In all vertebroplasty group specimens, the superior and inferior endplates of the untreated middle vertebral body (L2) were deflected, whereas 5 of the 6 nonvertebroplasty group specimens did not show any evidence of endplate deflection. CONCLUSION: Vertebroplasty altered the load transfer along the anterior spinal column, thereby statistically significantly increasing fracture risk and ultimate failure load of the untreated adjacent vertebrae. The radiographic findings support the endplate deflection fracture mechanism as the cause of adjacent fractures after vertebroplasty.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3