Can a Self-Expanding Aneurysm Stent Be Clipped? Emergency Proximal Control Options for the Vascular Neurosurgeon

Author:

Bell Randy S.123,Bank William O.12,Armonda Rocco A.123,Vo Alexander H.4,Kerber Charles W.5

Affiliation:

1. Neuro Interventional Service, Department of Radiology, Washington Hospital Center, Washington DC

2. Washington Brain and Spine, Washington, DC

3. National Naval Medical Center, Bethesda, Maryland

4. University of Texas Medical Branch, Galveston, Texas

5. University of California San Diego, San Diego California

Abstract

Abstract BACKGROUND: If a self-expanding stent has been placed during endovascular treatment of an aneurysm and subsequently an open aneurysm surgery becomes necessary in the same or an adjacent area, is it possible and safe to obtain proximal control by placing a temporary clip on the artery at a point where it contains the stent? OBJECTIVE: To evaluate the effect of temporary clip application to 3 separate stent systems in an in vitro flow model with the stated hypothesis that clip application to these stents will result in permanent stent deformation. METHODS: This is an in vitro flow model study using an accepted synthetic blood vessel substitute. The Neuroform3 (Boston Scientific), Enterprise (Cordis/Codman), and Pipeline (ev3) stents were deployed within the flow model; temporary clips were applied; and angiographic measurements subsequently made. RESULTS: Two 4 × 30-mm Neuroform3 stents, two 4.5 × 28-mm Enterprise stents, and two 3.75 × 20-mm Pipeline stents were successfully deployed and clipped repeatedly (4 iterations). Two- and 3-dimensional angiograms were obtained. After repeated clip occlusion, the Neuroform3 and Enterprise stents returned to their original configuration and diameter. Clip application to both also resulted in immediate flow arrest. In contrast, initial clip application to the Pipeline stents did not result in flow arrest, but the second single clip application did. The Pipeline stents were also irreversibly deformed after the experimental protocol, with an average luminal diameter reduction of 26.85% (P < .05). CONCLUSION: The Neuroform3 and Enterprise stents responded favorably to temporary clip application, returning to their original diameter after clip removal and showing no sign of permanent structural modification. The Pipeline flow-diverting stent, however, was irreversibly deformed by clip application. These data indicate that temporary clip application to certain stents is possible. Further in vivo study is required.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3