Radiological Outcomes of Static vs Expandable Titanium Cages After Corpectomy

Author:

Lau Darryl1,Song Yeohan1,Guan Zhe1,La Marca Frank2,Park Paul2

Affiliation:

1. University of Michigan Medical School, Ann Arbor, Michigan

2. Department of Neurosurgery, University of Michigan, Ann Arbor, Michigan

Abstract

Abstract BACKGROUND: Mesh cages have commonly been used for reconstruction after corpectomy. Recently, expandable cages have become a popular alternative. Regardless of cage type, subsidence is a concern following cage placement. OBJECTIVE: To assess whether subsidence rates differ between static and expandable cages, and identify independent risk factors for subsidence and extent of subsidence when present. METHODS: A consecutive population of patients who underwent corpectomy between 2006 and 2009 was identified. Subsidence was assessed via x-ray at 1-month and 1-year follow-ups. In addition to cage type, demographic, medical, and cage-related covariates were recorded. Multivariate models were used to assess independent associations with rate, odds, and extent of subsidence. RESULTS: Of 91 patients, 44.0% had expandable cages and 56.0% had static cages. One-month subsidence rate was 36.3%, and the 1-year subsidence rate was 51.6%. Expandable cages were independently associated with higher rates and odds of subsidence in comparison with static cages. Infection, trauma, and footplate-to-vertebral body endplate ratio of less than 0.5 were independent risk factors for subsidence. The presence of prongs on cages and posterior fusion 2 or more levels above and below corpectomy level had lower rates and odds of subsidence. Infection and cage placement in the thoracic or lumbar region had greater extent of subsidence when subsidence was present. CONCLUSION: Expandable cages had higher rates and risk of subsidence in comparison with static cages. When subsidence was present, expandable cages had greater magnitudes of subsidence. Other factors including footplate-to-vertebral body endplate ratio, prongs, extent of supplemental posterior fusion, spinal region, and diagnosis also impacted subsidence.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3