An Optimized System for Interventional Magnetic Resonance Imaging-Guided Stereotactic Surgery: Preliminary Evaluation of Targeting Accuracy

Author:

Larson Paul S.1,Starr Philip A.1,Bates Geoffrey2,Tansey Lisa2,Richardson R. Mark1,Martin Alastair J.3

Affiliation:

1. Department of Neurological Surgery

2. Department of Radiology, University of California, San Francisco, San Francisco, California

3. Department of MRI Interventions, Inc. (formerly SurgiVision, Inc.), Irvine, California

Abstract

Abstract BACKGROUND: Deep brain stimulation electrode placement with interventional magnetic resonance imaging (MRI) has previously been reported using a commercially available skull-mounted aiming device (Medtronic Nexframe MR) and native MRI scanner software. This first-generation method has technical limitations that are inherent to the hardware and software used. A novel system (SurgiVision ClearPoint) consisting of an aiming device (SMARTFrame) and software has been developed specifically for interventional MRI, including deep brain stimulation. OBJECTIVE: To report a series of phantom and cadaver tests performed to determine the capability, preliminary accuracy, and workflow of the system. METHODS: Eighteen experiments using a water phantom were used to determine the predictive accuracy of the software. Sixteen experiments using a gelatin-filled skull phantom were used to determine targeting accuracy of the aiming device. Six procedures in 3 cadaver heads were performed to compare the workflow and accuracy of ClearPoint with Nexframe MR. RESULTS: Software prediction experiments showed an average error of 0.9 ± 0.5 mm in magnitude in pitch and roll (mean pitch error, −0.2 ± 0.7 mm; mean roll error, 0.2 ± 0.7 mm) and an average error of 0.7 ± 0.3 mm in X-Y translation with a slight anterior (0.5 ± 0.3 mm) and lateral (0.4 ± 0.3 mm) bias. Targeting accuracy experiments showed an average radial error of 0.5 ± 0.3 mm. Cadaver experiments showed a radial error of 0.2 ± 0.1 mm with the ClearPoint system (average procedure time, 88 ± 14 minutes) vs 0.6 ± 0.2 mm with the Nexframe MR (average procedure time, 92 ± 12 minutes). CONCLUSION: This novel system provides the submillimetric accuracy required for stereotactic interventions, including deep brain stimulation placement. It also overcomes technical limitations inherent in the first-generation interventional MRI system.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Clinical Neurology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3