Affiliation:
1. Department of Neurosurgery, Mount Sinai School of Medicine, New York, New York
Abstract
Abstract
BACKGROUND:
A variety of imaging strategies may be used to derive reliable stereotactic coordinates when performing deep brain stimulation lead implants. No single technique has yet proved optimal.
OBJECTIVE:
To compare the relative accuracy of stereotactic coordinates for the subthalamic nucleus (STN) derived either from fast spin echo/inversion recovery (FSE/IR) magnetic resonance imaging MRI alone (group 1) or FSE/IR in conjunction with T1-weighted spoiled gradient-echo MRI (group 2).
METHODS:
A retrospective analysis of 145 consecutive STN deep brain stimulation lead placements (group 1, n = 72; group 2, n = 73) was performed in 81 Parkinson disease patients by 1 surgical team. From the operative reports, we recorded the number of microelectrode recording trajectories required to localize the desired STN target and the span of STN traversed along the implantation trajectory. In addition, we calculated the 3-dimensional vector difference between the initial MRI-derived coordinates and the final physiologically refined coordinates.
RESULTS:
The proportion of implants completed with just 1 microelectrode recording trajectory was greater (81% vs 58%; P < .001) and the 3-dimensional vector difference between the anatomically selected target and the microelectrode recording–refined target was smaller (0.6 ± 1.2 vs 0.9 ± 1.3; P = .04) in group 2 than in group 1. At the same time, the mean expanse of STN recorded along the implantation trajectory was 8% greater in group 2 (4.8 ± 0.6 vs 5.2 ± 0.6 mm; P < .001).
CONCLUSION:
A combination of stereotactic FSE/IR and spoiled gradient-echo MRI yields more accurate coordinates for the STN than FSE/IR MRI alone.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Clinical Neurology,Surgery
Reference34 articles.
1. Stereotactic localization using fast spin-echo imaging in functional disorders;Taren;Acta Neurochir Suppl (Wien),1993
2. Improved visibility of the subthalamic nucleus on high-resolution stereotactic mr imaging by added susceptibility (t2*) contrast using multiple gradient echoes;Elolf;AJNR Am J Neuroradiol,2007
3. Direct visualization of the human subthalamic nucleus with 3t mr imaging;Slavin;AJNR Am J Neuroradiol,2006
4. Neuroimaging and deep brain stimulation;Dormont;AJNR Am J Neuroradiol,2010
5. A high-resolution fast spin-echo inversion-recovery sequence for preoperative localization of the internal globus pallidus;Reich;AJNR Am J Neuroradiol,2000