An In Vitro Biomechanical Comparison of Single-Rod, Dual-Rod, and Dual-Rod With Transverse Connector in Anterior Thoracolumbar Instrumentation

Author:

Reddy Chandan G.1,Magnetta Michael2,Dahdaleh Nader S.1,Demmer Matthew2,Iyamah Kingsley Abode1,Lim Tae-Hong2,Torner James C.3,Hitchon Patrick W.1

Affiliation:

1. Department of Neurosurgery, University of Iowa, Iowa City, Iowa

2. Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa

3. Department of Epidemiology, University of Iowa, Iowa City, Iowa

Abstract

Abstract BACKGROUND: After thoracolumbar corpectomy, standard anterolateral instrumentation may consist of dual rods with cross-connectors. However, when the vertebral bodies are small or involved with disease, only 1 rod may be possible. OBJECTIVE: To compare the biomechanics of an in vitro L1 corpectomy model using 1 rod, 2 rods, or 2 rods with 2 cross-connectors. METHODS: Eight fresh frozen human cadaveric spines were potted from T9 to L3. Pure moments of 1.5, 3, and 4.5 Nm were applied, and the motion of the spine was measured using 3 infrared cameras. Loads were applied in flexion and extension, right and left lateral bending, and right and left axial rotation. Each spine was first tested in the intact state. After performing an L1 corpectomy and replacement with a carbon fiber reinforced polymer cage, 3 constructs were tested: single rod (1R), dual rod (2R), and dual rod with 2 transverse connectors (CC). RESULTS: Analysis of variance suggests significant main effects of load (P < .0001), axis (P = .022), construct (P =.0019), and individual spine (P < .0001). Overall, the single-rod construct is significantly less rigid than the intact spine in axial rotation. There is no significant difference between the intact spine and either the dual-rod construct or the dual-rod cross-connector construct. CONCLUSION: In our in vitro model of anterior spinal stabilization after corpectomy and grafting, a single-rod construct is significantly less rigid than the intact spine. Addition of a second rod returns the rigidity of the spine to the intact state. A dual-rod cross-connector construct is significantly more rigid than a single-rod construct.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Reference45 articles.

1. Kaneda anterior spinal instrumentation;Cohen,1995

2. Management options in thoracolumbar fractures;Hitchon;Contemp Neurosurg,2000

3. Thoracic and lumbar fractures: management analysis;Hitchon,1995

4. Recumbency in thoracolumbar fractures;Hitchon;Neurosurg Clin N Am,1997

5. Management options in thoracolumbar burst fractures;Hitchon;Surg Neurol,1998