Automated Three-dimensional Volume Rendering of Helical Computed Tomographic Angiography for Aneurysms: An Advanced Application of Neuronavigation Technology

Author:

Benvenuti Lucia1,Chibbaro Salvatore1,Carnesecchi Stefano1,Pulerà Flavio1,Gagliardi Rolando1

Affiliation:

1. Department of Neurosurgery, Livorno City Hospital, Livorno, Italy

Abstract

Abstract OBJECTIVE: To introduce the possibility of volume-rendered helical computed tomographic (CT) angiographic data sets by use of Medtronic StealthStation Treon surgical navigation technology (Medtronic Surgical Navigation Technologies, Louisville, CO) and to evaluate the clinical usefulness of the method in planning and performing surgical treatment of intracranial aneurysms. METHODS: Between November 2002 and July 2003, we studied 15 patients with suspected intracranial aneurysms. All patients but two received conventional digital subtraction angiography, which failed to provide the requested information. Helical CT angiography was performed in all patients, and data sets were transferred to the StealthStation system across an electronic network to be automatically postprocessed by use of three-dimensional (3-D) volume rendering. The 3-D volume-rendered images were accurately analyzed to obtain more complete information about the aneurysm and to provide accurate treatment planning. In all patients, the 3-D volume-rendered model was displayed on the screen of the StealthStation system for the duration of the surgical procedure and compared with the intraoperative image. RESULTS: Data sets from CT angiography were automatically postprocessed by the StealthStation in seconds with excellent results, providing us, before and during surgery, with additional information not always available on traditional digital subtraction angiographic investigation. Because of the very short time necessary to complete this process (<5 min to obtain 3-D volume-rendered images), it was possible to perform emergency clipping of the aneurysms in two patients who had been admitted in very compromised neurological conditions. In 12 patients, integrated digital subtraction angiography and automated 3-D volume-rendered images allowed an accurate presurgical evaluation. Furthermore, in all patients on whom surgery was performed, aneurysms were found in the exact location and with the same anatomic features as depicted by the 3-D volume-rendered models. CONCLUSION: Reports in the literature indicate that information gathered by CT angiography with volume rendering shows a significant impact on aneurysm management. The StealthStation system upgraded with the adequate algorithm seems to provide a time- and cost-effective method of performing automated 3-D volume rendering of CT angiography and provides an interesting alternative to the available investigation modalities in case of emergency.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Reference21 articles.

1. Image guided excision of a ruptured feeding artery “pedicle aneurysm” associated with an arteriovenous malformation in a child: Case report;Albert;Comput Aided Surg,1997

2. Distal anterior choroidal artery aneurysm in a patient with moyamoya disease: Case report;Batjer;Neurosurgery,2001

3. Image-guided system technology for intracranial aneurysms: A preliminary report;Benvenuti,2003

4. Three-dimensional volume rendering of spiral CT data: Theory and method;Calhoun;Radiographics,1999

5. Complementary use of computed tomographic angiography in treatment planning for posterior fossa subarachnoid hemorrhage;Carvi y Nievas;Neurosurgery,2002

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3