Stabilization of Anterior Cervical Spine with Bioabsorbable Polymer in One- and Two-level Fusions

Author:

Park Min S.1,Aryan Henry E.1,Ozgur Burak M.1,Jandial Rahul1,Taylor William R.1

Affiliation:

1. Division of Neurological Surgery, University of California, San Diego Medical Center, San Diego, California

Abstract

Abstract OBJECTIVE We present our experience using a bioabsorbable polymer in the surgical management of one- and two-level degenerative disc disease of the cervical spine with anterior cervical discectomy and fusion. Twenty-six patients were treated at the University of California, San Diego Medical Center or the Veterans Affairs Medical Center in San Diego, CA. All cases were performed under the direction of a single neurosurgeon (WRT). METHODS A retrospective review of patients' charts and imaging was performed to determine outcomes after anterior cervical spine operations. Specifically, we looked at the need for additional surgery, local reaction to the bioabsorbable polymer, fusion rate, and complications. Procedures involved the C3–C4, C4–C5, C5–C6, and/or C6–C7 levels, and fibular allograft was used in all but one case. The anterior cervical discectomy and fusion procedures with internal fixation were performed in 26 patients between March 2000 and November 2001. The patients were followed for up to 2 years after surgery (average, 14 mo). RESULTS Radiographic fusion was achieved in 25 (96.2%) of 26 patients. Only one instance of treatment failure was encountered that required additional surgery and the placement of a titanium plate. There were no clinical signs or symptoms of reaction to the bioabsorbable material. CONCLUSION The rates of fusion after single-level anterior cervical discectomy and fusion with internal fixation using bioabsorbable polymer and screws in this study match those using metallic implants, as previously reported in the literature, and are superior to those achieved with noninstrumented fusions. Preliminary results suggest that this newly available technology for anterior fusion is as effective in single-level disease as traditional titanium plating systems. The bioabsorbable material seems to be tolerated well by patients. A larger, randomized, controlled study is necessary to bring the results to statistical significance.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Reference19 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3