CYBERKNIFE STEREOTACTIC RADIOTHERAPY FOR SPINAL TUMORS

Author:

Thariat Juliette1,Castelli Joel1,Chanalet Stephane2,Marcie Serge1,Mammar Hamid1,Bondiau Pierre-Yves1

Affiliation:

1. Department of Radiation Oncology, Antoine Lacassagne Anti-Cancer Center, Sophia Antipolis University, Nice, France

2. Department of Radiodiagnostics, University Hospital Pasteur, Nice, France

Abstract

Abstract OBJECTIVE For para- and intraspinal tumors, precise spinal cord delineation is critical for CyberKnife (Accuray, Inc., Sunnyvale, CA) stereotactic radiotherapy. We evaluated whether computed tomographic (CT) myelography is superior to magnetic resonance imaging (MRI) for accurate spinal cord delineation. Treatment parameters and short-term outcome and toxicity are also presented. METHODS The planning CT scan, the gadolinium-enhanced, T1-weighted, 3-dimensional (3D) fast imaging employing steady-state acquisition MRI scan, and the CT myelogram were fused before volume-of-interest delineation. The planning target volume margin was less than 1 mm using the Xsight Spine tracking system (Accuray). We present data from 11 heavily pretreated patients who underwent CyberKnife stereotactic radiosurgery between November 2006 and January 2008. RESULTS Spatial resolution was 0.46 and 0.93 mm/pixel for CT myelography and 3D-fast imaging employing steady-state acquisition MRI, respectively. The contrast between cerebrospinal fluid and spinal cord was excellent with CT myelography. A transient postmyelography headache occurred in 1 patient. The mean gross tumor volume was 51.1 mL. The mean prescribed dose was 34 Gy in 4 fractions (range, 2–7 fractions) with 147 beams (range, 79–232 beams) to the 75% reference isodose line (range, 68–80%), covering 95% (range, 86–99%) of the gross tumor volume with a mean conformity index of 1.4 (range, 1.1–1.8). No short-term toxicity on the spinal cord was noted at 1- to 6-months of follow-up. CONCLUSION CT myelography was more accurate for spinal cord delineation than 3D-fast imaging employing steady-state acquisition MRI (used for its myelographic effect), particularly in the presence of ferromagnetic artifacts in heavily pretreated patients or in patients with severe spinal compression. Because other MRI sequences (T2 and gadolinium-enhanced T1) provide excellent tumor characterization, we suggest trimodality imaging for spinal tumor treatment to yield submillimetric delineation accuracy. Combined with CyberKnife technology, CT myelography can improve the feasibility of dose escalation or reirradiation of spinal tumors in selected patients, thereby increasing local control while avoiding myelopathy. Further follow-up and prospective studies are warranted.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3