Safety and Feasibility of Convection-enhanced Delivery of Cotara for the Treatment of Malignant Glioma: Initial Experience in 51 Patients

Author:

Patel Sunil J.1,Shapiro William R.2,Laske Douglas W.3,Jensen Randy L.4,Asher Anthony L.5,Wessels Barry W.6,Carpenter Susan P.7,Shan Joseph S.7

Affiliation:

1. Department of Neurological Surgery, Medical University of South Carolina, Charleston, South Carolina

2. Division of Neurology, Barrow Neurological Institute, St. Joseph's Hospital, Phoenix, Arizona

3. Neurosurgical Oncology, Temple University School of Medicine, Philadelphia, Pennsylvania

4. Department of Neurological Surgery, University of Utah Medical Center, Salt Lake City, Utah

5. Neurosurgery, Carolina Neurosurgery and Spine Associates, Charlotte, North Carolina

6. Department of Radiation Oncology, Case Western Reserve University, Cleveland, Ohio

7. Clinical Affairs, Peregrine Pharmaceuticals, Inc., Tustin, California

Abstract

Abstract OBJECTIVE: We report the safety and feasibility of using convection-enhanced delivery to administer Cotara (Peregrine Pharmaceuticals, Inc., Tustin, CA), a novel radioimmunotherapeutic agent, to patients with malignant glioma. METHODS: Between April 1998 and November 2002, 51 patients with histologically confirmed malignant glioma received Cotara by convection-enhanced delivery. Most patients (88%) were treated with Cotara targeting tumor volume-dependent, single or multiple administrations of activity ranging from 0.5 to 3.0 mCi/cm3 of baseline clinical target volume. Two weeks after infusion, single-photon emission computed tomographic imaging determined the spatial distribution of Cotara. Patients were followed for as long as 41 months (average follow-up, 5 mo). Safety was evaluated on the basis of incidence of procedure-related, neurological, and systemic adverse events. Feasibility was evaluated in a subset of patients on the basis of the correlation between the prescribed activity and the actual activity administered to the targeted region. RESULTS: Fifty-one patients, 37 with recurrent glioblastoma multiforme, 8 with newly diagnosed glioblastoma multiforme, and 6 with recurrent anaplastic astrocytomas, were treated. Average tumor volume was 36 ± 27.6 cm3 (range, 5–168 cm3). Of the 67 infusions, 13 (19%), 52 (78%), and 2 (3%) delivered less than 90%, 100 ± 10%, and more than 110%, respectively, of the prescribed administered activity to the targeted region. Treatment-emergent, drug-related central nervous system adverse events included brain edema (16%), hemiparesis (14%), and headache (14%). Systemic adverse events were mild. Several patients had objective responses to Cotara. CONCLUSION: The majority of Cotara infusions delivered between 90 and 110% of the prescribed administered activity to the targeted region. This method of administration has an acceptable safety profile compared with literature reports of other therapeutics delivered by convection-enhanced delivery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 143 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Breaking Barriers in Neuro-Oncology: A Scoping Literature Review on Invasive and Non-Invasive Techniques for Blood–Brain Barrier Disruption;Cancers;2024-01-04

2. Radionuclide Therapy in Brain Tumours;Beyond Becquerel and Biology to Precision Radiomolecular Oncology: Festschrift in Honor of Richard P. Baum;2024

3. Toxic warhead-armed antibody for targeted treatment of glioblastoma;Critical Reviews in Oncology/Hematology;2024-01

4. Drug Delivery to the Brain: Recent Advances and Unmet Challenges;Pharmaceutics;2023-11-23

5. Theranostic in glioblastoma;New Insights Into Glioblastoma;2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3